11. Generator option
Fig. 42
* Allow the engine to continue running for
about 2 minutes, so that the generator
cools down.
*
Stop the generator.
11.6 Technical characteristics of
110V 6kVA GTS generator
Generator model
WG 6,0-2ZE
Generator type
Synchronous,
internal pole,
electronically
controlled
Generator frame
B3/two bearings
Degree of protection
IP 54
Generator characteristics:
Extremely low dynamic internal resistance,
same output voltage whether hot or cold,
no dangerous overvoltage during dynamic
overspeed, small reactive effect from non-
linear or very inductive equipment, trouble-
free operation of equipment with phase
control, no dangerous overvoltage of the
unloaded phases, load current may have
significant DC components
Power system
(IEC 38/50Hz)
1-phase AC
2 x 115V
Amplified phases
3
Nominal output
(0.8 cap/ind)
7000VA
Nominal current
32A + 2 x 16A
Startup current
4.1 times I
Operating mode
S1, continuous
Protective measure
Electrical isolation,
with equipotential
bonding conductor
in accordance with
VDE 0100.728
Coolant
Air/externally
ventilated with own
fan, independent of
direction of rotation
Nominal speed for
nominal frequency
3000 rpm
Min. speed for
nominal output
3000 rpm
Efficiency at nominal output
at 0.8 ind
at 1.0
Distortion factor
Weight
Overall size
Overall length
Generator regulator
Model
Connector assignment
8 pole
4-pole
Switchbox
Degree of protection IP 54
Dimensions
Design
Fusing
Insulation monitoring
Model
Controls
Areas of application
engines difficult to get running, welding
devices (incl. inverters), pumps,
compressors, tools, construction
machinery, illumination
Generator data
Winding
Colour
U1-N
brown-blue
U2-N
black-blue
W-N
black-blue
ZU-ZN
yellow-yellow
ZV-ZN
yellow-yellow
rated
ZW-ZN
yellow-yellow
1F1-1F2
red-grey
(All resistances measured using the 4-wire
R method)
0.80
0.82
< 5%
53 kg
BG132
357 mm
LCAR3
Pin
Colour
Function
1
red
F1
2
grey
F2
3
not assigned
4
yellow
ZU
5
yellow
ZV
6
yellow
ZW
7
brown
L1
8
blue
N
1
black switch contact
2
black switch contact
3
not assigned
4
not assigned
250x204x135
Front panel type
All poles
U1
C32A
U2
2 x 16A
GMW-RISO1.0
Red test button
Ins. class
Resistance
(at 20°C)/Ω
F
0.165
F
0.165
F
0.28
F
2.5
F
2.5
F
2.5
H
22.1
11.7 Technical characteristics of
400/230V 5/8kVA GTS
generator
Generator model........ DWG 8/5-2-ZE
Generator type........... Synchronous,
internal pole,
electronically
controlled
Generator frame ........ B3/two bearings
Degree of protection .. IP 54
Generator characteristics:
Extremely low dynamic internal resistance,
same output voltage whether hot or cold,
no dangerous overvoltage during dynamic
overspeed, small reactive effect from non-
linear or very inductive equipment, trouble-
free operation of equipment with phase
control, no dangerous overvoltage of the
unloaded phases, load current may have
significant DC components
Power system
(IEC 38/50Hz)
3-phase AC
400V/230V
Nominal output (0.8 cap/ind)
single-phase
5000VA
3-phase (sym)
8000VA
Nominal current
single-phase
21.6A
3-phase (sym)
11.5A
Startup current
4.1 times I
Operating mode
S1, continuous
Protective measure
Electrical isolation,
with equipotential
bonding conductor
in accordance with
VDE 0100.728
Coolant
Air/externally
ventilated with own
fan, independent of
direction of rotation
Nominal speed for
nominal frequency
3000 rpm
Min. speed for
nominal output
3000 rpm
Efficiency at nominal output
at 0.8 ind
0.80
at 1.0
0.82
Distortion factor
< 5%
Weight
53 kg
Overall size
BG132
Overall length
357 mm
Generator regulator
Model
LCAR 3
Connector assignment
8 pole
Pin Colour Function
1
red
2
grey
3
violet 1/2U
4
violet 1/2V
5
violet 1/2W
rated
F1
F2
41