Frequent Inspection; Periodic Inspection - Harrington ER2 SERIES Owner's Manual

1/8 ton through 5 ton capacity electric chain hoist
Hide thumbs Also See for ER2 SERIES:
Table of Contents

Advertisement

5.3

Frequent Inspection

5.3.1
Inspections should be made on a FREQUENT basis in accordance with
Inspection." Included in these FREQUENT Inspections are observations made during operation for
any defects or damage that might appear between Periodic Inspections. Evaluation and resolution of
the results of FREQUENT Inspections shall be made by a designated person such that the hoist is
maintained in safe working condition.
All functional operating mechanisms for maladjustment and unusual sounds.
Operation of limit switch and associated components
Hoist braking system for proper operation
Hooks in accordance with ANSI/ASME B30.10
Hook latch operation
Load chain in accordance with
Load chain reeving for compliance with
5.4

Periodic Inspection

5.4.1
Inspections should be made on a PERIODIC basis in accordance with
Evaluation and resolution of the results of PERIODIC Inspections shall be made by a designated
person such that the hoist is maintained in safe working condition.
5.4.2
For inspections where load suspension parts of the hoist are disassembled, a load test per ANSI/ASME
B30.16 must be performed on the hoist after it is re-assembled and prior to its return to service.
Requirements of frequent inspection.
Evidence of loose bolts, nuts, or rivets.
Evidence of worn, corroded, cracked, or distorted parts such as load blocks, suspension housing,
chain attachments, clevises, yokes, suspension bolts, shafts, gears, bearings, pins and rollers.
Evidence of damage to hook retaining nuts or collars and pins, and welds or rivets used to secure
the retaining members.
Evidence of damage or excessive wear of load and idler sheaves.
Evidence of excessive wear on motor or load brake.
Electrical apparatus for signs of pitting or any deterioration of visible controller contacts.
Evidence of damage of supporting structure or trolley, if
Function labels on pendant control stations for legibility.
Warning label properly attached to the hoist and legible (see
End connections of load chain.
Table 5-1
Frequent Inspection
Section 5.7
Section 3.2 and 6.5
Table 5-2
Periodic Inspection
used.