2.2 Ventilation requirements

The room containing the appliance should have an air supply in accordance with
B.S. 5440 part 2 1989.
1.
All rooms require an opening window or equivalent, and some rooms will
require a permanent vent as well.
2.
For room volumes up to 5 m
3.
If the room has a door that opens directly to the outside, and the room
3
exceeds 1 m
no air vent is required.
4.
For room volumes between 5 m
5.
If there are other fuel burning appliances in the same room B.S. 5440 part 2
1989 should be consulted to determine the air vent requirements.
6.
This appliance must not be installed in a bed sitting room of less than 20 m
or in a bathroom or shower room.
Windows and permanent vents should therefore not be blocked or removed
without first consulting a Corgi gas installer.
Failure to install appliances correctly is dangerous and could lead to
prosecution.