Page 1
The contents of this guide may be reproduced or reprinted in whole not be reproduced or reprinted or in part without the express written in whole or in part without the permission of DVTEL, INC. express written permission of Rev 1 February 2015 DVTEL, INC.
Reset by Removing the Power Supply ..............15 Appendix ..........................16 A.1. Technical Specifications ..................17 A.2. Connecting Leads to a Spring Clamp Terminal Block ..........19 A.3. Troubleshooting ...................... 20 A.4. N/O to N/C Relay Configuration ................22 Contacting DVTEL ......................23...
Page 4
List of Figures Figure 1: trk-101-P Unit ......................1 Figure 2: trk-101-P Unit Connectivity ..................1 Figure 3: trk-101-P Power Connection Panel ................2 Figure 4: trk-101-P Video Connection Panel ................4 Figure 5: trk-101-P with Nuts Removed ..................6 Figure 6: Inserting Units into Rack Mount Panel ................
A Tip is information and best practices that are useful or provide some benefit for installation and use of DVTEL products. Un Conseil correspond à une information et aux bonnes pratiques utiles ou apportant un avantage supplémentaire pour l'installation et l'utilisation des produits DVTEL.
Page 7
DVTEL, Inc. et ses agents ne garantissent d'aucune DVTEL, Inc. and its agents make no guarantees or façon que les produits sont adaptés à l'usage auquel warranties to the suitability for the users’...
Page 8
Installation Manual Warning: 1. The unit’s cover is an essential part of the product. Do not open or remove it. 2. Never operate the unit without the cover in place. Operating the unit without the cover poses a risk of fire and shock hazards 3.
Page 9
Document Information Electrical Safety Notice and Warnings Warning: 1. Read the installation instructions before you connect the unit to a power source 2. Electrical safety should always be observed. All electrical connections must be performed by a certified electrician. 3. Use the supplied power supply and protect against static electricity, ground faults and power surges.
Page 10
Installation Manual Avis et avertissements relatifs à la sécurité électrique Avertissement: 1. Lisez les instructions d'installation avant de brancher l'unité à une source d'alimentation électrique. 2. Les consignes de sécurité électrique doivent toujours être respectées. Toutes les connexions électriques doivent être effectuées par un électricien qualifié.
Page 11
Document Information Minimizing EMI and RFI Minimisation des IEM et des IRF When wires run for a significant distance in an Lorsque des câbles parcourent une distance electromagnetic field, electromagnetic importante dans un champ électromagnétique, des interference (EMI) can occur. Strong EMI (e.g. interférences électromagnétiques (IEM) peuvent se lightning or radio transmitters) can destroy the produire.
Introduction 2. Introduction The trk-101-P PTZ Tracker is a single-channel, self-contained H.264 IP video analytic encoder that is designed to control and monitor the video input from an analog PTZ camera. Once a moving object has been detected, the unit controls and moves the PTZ camera to autonomously track and zoom in on the threat.
Related Documentation: HTML Edition Units User’s Guide ioi Product Selection Matrix trk-101 and trk-101-P Quick Install Guide DNA 2.0 User Manual 2.2 Hardware Description This section describes the connection panels of the unit. 2.2.1 Power Connection Panel The following is a description of the power connection panel of the unit.
Page 15
Introduction Item Description RESET Button For setting the unit factory defaults, setting Technician mode, or resetting the unit. LEDs The LEDs indicates several status conditions: Off: The unit is resetting. Flashing green (300ms intervals): The firmware is booting. ...
Installation Manual 2.2.2 Video Connection Panel The following is a description of the video connection panel of the unit. Figure 4: trk-101-P Video Connection Panel The video connection panel of the unit includes the following items: Item Description VIDEO OUT...
Installing and Connecting the Unit 3. Installing and Connecting the Unit This section describes how to install and connect the unit and includes the following sections: Installing the Unit (page 5) Connecting the Unit (page 7) Resetting the Unit (page 14) Note: After connecting the unit, proceed to configure the unit as described in the HTML Edition...
1. Remove the nut and washer from each of the two video connectors on the video connection panel of the unit. Figure 5: trk-101-P with Nuts Removed 2. Attach each unit to the rear side of the rack mount panel by inserting it through the holes as...
To ground the unit 1. Loosen the screw of the grounding terminal located on the power connection panel of the unit. Figure 3: trk-101-P Power Connection Panel. 2. Attach a properly rated ground cable. Make sure the ring/spade terminal of the grounding cable is between the toothed washers.
By default, the unit is shipped with the factory default IP address 192.168.123.10. The DVTEL Network Assistant (DNA) utility is used to discover the unit on the network and to configure it. DNA provides a central location for listing all the DVTEL models accessible over the network. Once listed, each camera or encoder can be right-clicked to access and change the network settings.
Installing and Connecting the Unit To change the unit’s IP address 1. Insert the CD included in the package in your computer’s disk drive. Note: The PC and the unit must be physically connected on the same subnet. 2. Run the dna.exe file by clicking the icon.
Installation Manual 6. For each unit, do one of the following: If your network uses a DHCP server: Select Use DHCP. ii. Click Update. A new IP address is automatically assigned to the selected device(s) by the network DHCP server.
2. Connect the other cable end to the VIDEO IN connection on the video connection panel of the unit. See Figure 4: trk-101-P Video Connection Panel (page 4). To set the unit’s video standard via its web interface 1.
Installation Manual 3.2.5 Configuring PTZ Camera Settings on the Encoder PTZ camera settings are configured in the Setup > Camera > Type & Model screen in the web interface. Figure 12: Camera > Type & Model Screen To configure PTZ camera settings on the encoder 1.
2. Connect the terminal block to the external devices connector on the power connection panel of the unit. See Figure 3: trk-101-P Power Connection Panel (page 2). 3. Connect the other end of the cable to the alarm out (dry contact) of the alarm device/sensor.
2. Connect the terminal block to the external devices connector on the power connection panel of the unit. See Figure 3: trk-101-P Power Connection Panel (page 2). 3. Connect the other end of the cable to the external controller, which receives the signal from the unit and controls/powers the external device.
Installing and Connecting the Unit 3.3.2 Reset by Removing the Power Supply The unit can be reset by turning off the power and then turning it on again. To reset a unit by removing the power supply 1. Turn off or disconnect the power to the unit. 2.
Installation Manual Appendix The appendix contains the following sections: Technical Specifications (page 17) Connecting Leads to a Spring Clamp Terminal Block (page 19) Troubleshooting (page 20) NO to NC Relay Configuration (page 22)
Appendix A.1. Technical Specifications Following are the trk-101-P technical specifications: Video Input Channels Number of Intelligent Video Analysis Channels Analog Video Output TV Standard Composite 1Vp-p (PAL or NTSC) Physical Connector 1 x BNC 75Ω Digital Encoding IP Video Streaming H.264, MPEG 4 SP, and MJPEG...
Page 30
Installation Manual Physical Dimensions Dimensions (mm) 68.5 x 36 x 118 mm (W x H x D) Dimensions (in.) 2.7 x 1.42 x 4.62” (W x H x D) Environmental Specifications Operating 0° to 60°C (32° to 140°F) Temperature...
Appendix A.2. Connecting Leads to a Spring Clamp Terminal Block The unit is delivered with two terminal block connectors. The connectors enable you to connect wires for either the Relay Output or Alarm Input and then connect them to the unit. Figure 14: Spring Clamp Terminal Block To connect a wire to the spring clamp terminal block: 1.
Installation Manual A.3. Troubleshooting This section provides useful information and remedies for common situations where problems may be encountered. Problem Possible Solution No network connection Hardware issues: Check that the network is working and the unit is powered on.
Page 33
Appendix Problem Possible Solution Bad output video quality Check the source video signal quality by connecting an analog monitor to the video source. If video quality is acceptable, connect the video source to the unit. Check that the cables are connected securely. This includes junction boxes and amplifier that may be used.
A.4. N/O to N/C Relay Configuration The on-board relay in the trk-101-P provides a single contact which is by default NORMALLY OPEN (N/O), enabling it to be configured to CLOSED upon an alarm condition. This is usually configured with a momentary closure (for example, five seconds), followed by returning to the OPEN condition, to be ready for the next alarm event.
Mobile: +852 9479 4195 電郵: info.northasia@dvtel.com info.northasia@dvtel.com To request the latest versions of firmware and software or to download other product-related documents, visit http://www.dvtel.com/support. If you have obtained a login, go to our support gateway. For assistance, email us at support@dvtel.com...