  • Page 1 Pneumatic pressure pump P4 for low pressures up to 4 bar. Please keep this operating manual for future reference. If the appliance is resold, please provide the operating manual along with it.
  • Page 2: Table Of Contents

    Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. © SIKA • Ba_P4 • 04/2014...
  • Page 3: About This Operating Manual

    Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7-9 • D - 34260 Kaufungen  05605-803 0 •  05605-803 54 info@sika.net • www.sika.net Hazard symbols and other symbols used: CAUTION! Risk of injury in the case of excessive pressure! This sign indicates dangers which could arise from excessive pressure in a piece of equip- ment.
  • Page 4: Device Description

    Device description Device description The P4 pressure pump is used for checking, adjusting and calibrating all kinds of pressure equipment. It was specifically developed for low pressures up to 4 bar. It is also possible to generate negative pressure, but this is very dependent on the test chamber volume.
  • Page 5: Intended Use

    1.1 Intended use The P4 pressure pump may only be used for the generation of air pressure. Use with any other media, particularly hydraulic oil, will result in damage to the pressure pump. The pressure pump may not be attached to external pressure sources.
  • Page 6: Safety Instructions

    Qualified personnel: The personnel who are charged for the installation and operation of the P4 must hold a relevant qualification. This can be based on training or relevant tuition. The personnel must be aware of this operating manual and have access to it at all times.
  • Page 7: Construction And Function

     Pressure hose with cap screw (test item connection). Function: The correct functioning of the P4 pressure pump requires the pressure-proof connection of a reference and a test item . The test item respectively the pressure device to be tested (hereafter referred to as 'test item') is connected to the cap screw of the pressure hose ...
  • Page 8: Commissioning

    Before using the device, check that  the reference gauge is connected to the pressure pump.  the test item is joined to the pressure hose.  all pressure connections are correctly in place, so that they resist pressure. © SIKA • Ba_P4 • 04/2014...
  • Page 9: Generating Pressure

    Operation 5.1 Generating pressure CAUTION! Damage to test item! Adhere to the maximum pressure of the test item! Only create an admission pressure with the pump that is lesser than the necessary test- ing pressure. Following this carefully increase the pressure using the fine adjustment valve.
  • Page 10: Generating Negative Pressure

    To do this, turn the valve knob clockwise up to the limit stop. Generating negative pressure:  Turn the fine adjustment valve hand wheel counter-clockwise in the direction of the “Pressure relief valve limit stop” until the required negative pressure is attained. © SIKA • Ba_P4 • 04/2014...
  • Page 11: Carrying Out And Ending Measurements

    Operation 5.3 Carrying out and ending measurements For adjustments, calibrations or an inspection of accuracy, it is vital that the test item and the reference have the same pressure or negative pressure. The pressure or negative pressure needed for the test points is built up and adjusted with the pressure pump (...
  • Page 12: Problems

    (generating negative pressure). Seal incorrectly positioned. Check positioning of seal. Pressure relief valve open. Close pressure relief valve. Pressure or negative pressure Leakage in the test item. Check connections. fades (unstable). Check positioning of seals. © SIKA • Ba_P4 • 04/2014...
  • Page 13: Maintenance, Cleaning, Storage And Transportation

    Maintenance, cleaning, storage and transportation Maintenance, cleaning, storage and transportation Maintenance: No maintenance is required for the pressure pump and it cannot be repaired by the operator either. In the case of a defect the appliance must be sent back to the manufacturer for repair. ...
  • Page 14: Disposal

     all mounted parts were removed from the pressure pump. Disposal: No household waste! The pressure pump P4 consists of various different materials. It should not be disposed of with household waste.  Take the P4 to your local recycling plant ...
  • Page 15: Technical Data

    Technical data Technical data Type Pump with hose Medium: Pressure range: - Positive pressure 4 bar - Negative pressure -0,3 bar (depending on test item / Reference) Connection: - Reference G ¼ and Quick-Snap Y-plug connection with PA hose (2 x 1 m) - Test item G ¼...