American Time SiteSync IQ Installation And Operation Manual

Wireless controller

Advertisement

Installation and Operation Manual
Wireless Controller
Part # H004417
Rev. 2
December 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SiteSync IQ and is the answer not in the manual?

Questions and answers

Summary of Contents for American Time SiteSync IQ

  • Page 1 Installation and Operation Manual Wireless Controller Part # H004417 Rev. 2 December 2013...
  • Page 2 Safety Precautions All electrical power and signal wiring connected to the SiteSync IQ Wireless Controller, secondary clocks and signaling devices must be installed by qualified persons in conformance with applicable national and local electrical codes. Improper installation of this equipment can result in lethal electrical shock and fire.
  • Page 3: Table Of Contents

    Testing Operaton of Wireless Signal Circuits ....................... 8 Troubleshooting ................................... 9 Appendix A: Wall Hanging Diagram ............................. 10 Appendix B: Relay Wiring Diagram .............................. 11 Appendix C: Clock Relay Wiring Diagram ............................ 12 Appendix D: Replacing Fusess ..............................13 © American Time...
  • Page 4: Introduction

    Synchronization and event programming are achieved wirelessly from a SiteSync IQ Wireless System Controller. Manual control of signal circuits is achieved wirelessly via commands from a SiteSync IQ Wireless System Controller (keypad or Remote Connect Web Interface) or via panel switches on the front of the Wireless Controller.
  • Page 5: Wireless Controller Installation

    CAUTION To prevent damage to relays, relay contact voltage must not exceed 240vac. Appendix B shows wiring connections to the SiteSync IQ Wireless Controller and secondary clocks for all clock types controlled by the SiteSync IQ Wireless Controller. Signal Circuit Connections CAUTION To prevent damage to relays, relay contact voltage must not exceed 240vac.
  • Page 6: Operation

    15. Relay Output Fuses A power switch (#1) is located on the left side of the SiteSync IQ Wireless Controller. When power is connected and the power switch is in the on position the power LED (#2) located in the top right corner of the front panel will light red.
  • Page 7: Tone

    (use Tone Selection Table above). The tones will be assigned to the trigger terminals in the order they fall into from A to H where the first tone selected on the way from A to H is assigned to SiteSync IQ System Controller circuit 1, the next tone selected is assigned to circuit 2, and so on.
  • Page 8: Testing Operaton Of Wireless Signal Circuits

    Testing Wireless Operation of Signal Circuits Signal circuits can be controlled manually with the MAN key on the SiteSync IQ System Controller acting as a momentary push- button switch. To initiate manual wireless control: Using the SiteSync IQ System Controller Press MAN, enter User Lock (unless User Lock is disabled) and press OK (unless User Lock is disabled).
  • Page 9: Troubleshooting

    SiteSync IQ Wireless Controller power LED OFF when power is connected • Verify power switch is in the ON position • Disconnect power to the SiteSync IQ Wireless Controller and remove the junction box cover. Restore power and carefully check for 120vac between terminals H and N.
  • Page 10: Appendix A: Wall Hanging Diagram

    Appendix A: Wall Mounting Diagram SiteSync IQ Wireless Controller Installation Manual Note: This diagram is not to scale. © American Time...
  • Page 11: Appendix B: Relay Wiring Diagram

    OFF position. Contact American Time Technical Support with any questions at 800-328-8996. 6. Apply power to the Wireless Controller and signal circuit(s). 7. Test the signal circuits using the Sitesync IQ System Controller circuit menu or Remote Connect circuit tab. Example...
  • Page 12: Appendix C: Clock Relay Wiring Diagram

    Wired Clock Circuit Installation To install wired clock circuits: 1. Disconnect and lock out power to the SiteSync IQ Wireless Controller and any circuit wiring. 2. Remove the cover from the Wireless Controller. a. Remove 2 screws from each side of the wire compartment cover.
  • Page 13: Appendix D: Replacing Fusess

    Appendix D: Replacing Fuses SiteSync IQ Wireless Controller Installation Manual H004408 H004406 Part Number Description Where used H004406 Fuse 2A 250V 5x20 Fast Glass, SSIQ Power input (F2) WRLS CNTR H004408 Fuse 8A 250V 5x20 Fast Glass, SSIQ Relay contacts (F3-F8) WRLS CNTR ©...