Sabre ELSA Dash User Instruction

Sabre ELSA Dash User Instruction

Compressed air escape breathing apparatus
Hide thumbs Also See for ELSA Dash:

Advertisement

ELSA
DASH/SPRINT
Compressed Air Escape Breathing Apparatus
User Instructions
Article No. 1034931
Issue G
01. 2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELSA Dash and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sabre ELSA Dash

  • Page 1 ELSA DASH/SPRINT Compressed Air Escape Breathing Apparatus User Instructions Article No. 1034931 Issue G 01. 2007...
  • Page 2: Table Of Contents

    MONTHLY CHECKS ......................10 5.3.1 Check Apparatus ....................10 5.3.2 Upon Completion ....................11 Sabre Breathing Apparatus is a division of Scott Health and Safety Limited. Registered Office: Scott Health and Safety Limited, Pimbo Road, West Pimbo, Skelmersdale, Lancashire, WN8 9RA, United Kingdom.
  • Page 3: Warnings

    Check apparatus daily when issued to wearers or deployed in ready-use lockers; or monthly if held in stores. • ELSA Dash and Sprint are escape apparatus. DO NOT use for other purposes such as fire fighting or cargo handling. •...
  • Page 4: Introduction

    • Hazards likely to be encountered Providing that ELSA apparatus is serviced and their effect on the wearer. regularly as described in the ELSA Dash • Physical and emotional stress and and ELSA Sprint Service Manuals, there their effect on wearer breathing rate.
  • Page 5: Use In Explosive Or Flammable Atmospheres

    TRANSPORTATION Dash is a constant flow apparatus with a It is essential that ELSA Dash and ELSA flow rate of 38 litres per minute; that Sprint transported suitably consists of a compressed air cylinder with a pressure reducing valve (reducer), protective packaging.
  • Page 6: Hoods (Dash/Sprint)

    Providing apparatus serviced regularly in accordance with the service requirements, detailed in the ELSA Dash, or ELSA Sprint Service Manual, there are no shelf life limits. Dash and Sprint must be stored away from direct heat and sunlight. They can be stored and operated between -15°...
  • Page 7: Reducer Valve (Dash/Sprint)

    ELSA DASH/SPRINT REDUCER VALVE (DASH/SPRINT) The reducer is a simple, automatic spring and piston device, which screws into the charging adaptor of the cylinder valve and must be removed to charge the cylinder. It is attached to the cylinder using the handwheel.
  • Page 8: Storage Bag

    • The anti-tamper tag is in place. arm. • The contents gauge shows that the QUALITY ATTRIBUTES cylinder is full. ELSA Dash and Sprint are approved to: DONNING • 1993 (Respiratory protective devices for escape). • Lloyds...
  • Page 9: Hood (Dash/Sprint)

    ELSA DASH/SPRINT Hold the hood with the neck seal over the crown of the head and pull the If the quick-fire cord is not fitted, turn hood down over the head until the neck the cylinder valve handwheel fully anti- seal is around the neck.
  • Page 10: Facemask (Sprint)

    ELSA DASH/SPRINT FACEMASK (SPRINT) 4. AFTER USE CLEANING AND TESTING CLEANING HOODS (DASH/SPRINT) Disconnect the breathing hose: Dash only: Hold a lower harness strap in each hand. Unclip exhale valve cover and pull the exhale valve from its housing. Withdraw the elbow retaining U-clip and withdraw the elbow.
  • Page 11: Cleaning Facemasks

    ELSA DASH/SPRINT Wipe the surface of the hood, CLEANING FACEMASKS breathing hose and bag using a clean lint- CAUTION: free cloth moistened in a solution of Ensure visor is not scratched or TriGene (Article Numbers 2008247 for 1 contaminated with oil or grease while litre, or 2008248 for 5 litres) and warm cleaning.
  • Page 12: Breathing Apparatus Log

    ELSA DASH/SPRINT Release the cylinder retaining strap Fit the cylinder into the bag and and withdraw the cylinder from the bag. arrange the contents gauge so that it can be seen clearly when the bag is closed. Secure the cylinder with the retaining strap and buckle.
  • Page 13: Workshop Repair And Annual Servicing

    AND ANNUAL SERVICING MAINTENANCE Apparatus must be returned for workshop GENERAL servicing annually or if a malfunction occurs (see ELSA Dash or ELSA Sprint It is a mandatory requirement that all Service Manual). escape apparatus shall be checked at monthly intervals.
  • Page 14: Upon Completion

    ELSA DASH/SPRINT Connect the demand valve to the Hoods (Dash/Sprint): facepiece. If it is a first breath demand Check that there are no splits in the valve, press the reset button and connect fabric of the hood, visor or neckseal.
  • Page 15 Sabre Breathing Apparatus !"" # $% &' ( )&&)&& * + !"" # $% &' ( )&&))(...

This manual is also suitable for:

Elsa sprint