Fixed Bracket - Bray 5A Series Installation, Operation And Maintenance Manual

Valve status monitor
Table of Contents

Advertisement

6. Place lock washers on foot plate mounting
bolts.
7. Attach two mounting bracket foot plates to
the quarter-turn device.
a. Tighten mounting bracket foot plates to
44.3 in-lbs. [5Nm]
30 x 80
NAMUR pad
8. Attach coupler or adapter if provided.
9. Adjust the VSM cam shaft to align with the
actuator shaft or coupler.
a. Adjust bracket plates as needed.
10. Connect the mounting bracket top plate to
both bracket feet using bolts.
a. Adjust height of the bracket by choosing
mounting hole.
b. Tighten bolts to 44.3 in-lbs. [5Nm]
6
Series 5A and Series 5B Valve Status Monitor
Installation, Operation and Maintenance Manual

8.2 Fixed Bracket

Bray's single piece bracket is used for NAMUR
pattern 30 x 80. Installation is as follows:
1. Attach mounting bracket and nylon washers
2. Place VSM and bracket assembly on actuator.
30 x 130
NAMUR pad
3. Install bracket mounting bolts with lock
to the VSM using mounting bracket bolts.
a. Tighten mounting bolts in a cross
pattern to 70.8 in-lbs. [8Nm]
b. Ensure that the bracket remains aligned
with the body of the VSM.
Ensure VSM shaft engages with actuator
pinion.
washers as seen below.
a. Tighten mounting bracket bolts to
44.3 in-lbs. [5Nm].

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5b series

Table of Contents