RECHARGING THE UNIT
The charging circuitry in your unit utilizes a multi-phase, smart charging routine for more beneficial charging of the
onboard battery for enhanced reserve capacity and longer battery life.
The charging circuitry features the ability to properly charge both Standard Flooded and AGM batteries. This is an
important enhancement, as AGM batteries are designed for better cycling (charge/discharge) longevity and are spill-
proof, which is important in a mobile application such as this.
• All units ship with the charging mode set to the Standard Flooded Battery charging setting. This setting should be
changed if you choose to install an AGM battery in your unit. To change this setting, locate the control switch on the
charging board inside the unit and change the setting to AGM mode.
• Take care to ensure that cables and clamps are properly stored and secure and that the AC power cord is not
damaged in any way.
• Connect the AC power cord to a properly grounded outlet.
• The charging routine is fully automatic and will bring the onboard battery to full charge and then turn off. The charger
will turn back on if the battery discharges for any reason.
• The charger can be left connected to the AC outlet with no harm to the onboard battery.

TROUBLESHOOTING

PROBLEM: Unit does not jump start.
POSSIBLE CAUSE
Poor grip connection
Low/defective battery
Loose jumper cable connection to battery
PROBLEM: Unit does not charge.
POSSIBLE CAUSE
Poor grip connection
Faulty 110 AC outlet
Bad plug on unit
Loose/defective connections
Defective amp gauge
Faulty charger
PROBLEM: Unit does not inflate tires.
POSSIBLE CAUSE
Low/defective battery indicated by clicking of circuit breaker
Loose/defective connections
Defective air pressure switch
Defective "On/Off" switch
Defective compressor
For Diagnostic and Repair Help, call the Clore Automotive
Technical Service Hot Line at (800) 328-2921 or visit www.solaronline.com
SOLUTION
Check grip connection
Load test/charge/replace battery
Tighten battery connections
SOLUTION
Check grip connection
Check or change outlet
Check continuity of plug pins/replace plug
Check unit for loose connections
Replace gauge
Replace charger
SOLUTION
Recharge/replace battery
Check unit for loose connections
Replace pressure switch
Replace "On/Off" switch
Replace compressor