INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000

3.3. ECOSOFT ROBUST WITH PRESSURE TANK AND ULTRAVIOLET UNIT

Purified water. Tube from the pure water outlet to the ultraviolet unit.
Pressure tank. Tube from the tank outlet to the valve on the tank.
Drain. Tube from the drain outlet to the drain saddle.
Inlet. Water supply tube from the water main.
Ultraviolet unit*. The tube from the UV unit outlet to the purified water faucet.
*UV unit — optional equipment, not included in the delivery.
The system must be connected by the service center specialist.

4. INSTALLATION STEPS

Carefully read this manual before installing the reverse osmosis system.

4.1. INSTALLATION CONDITIONS CHECK

Check that feed water meets requirements in p. 2.2.
If the water quality does not meet requirements, refer to a water treatment specialist company
for assistance selecting the appropriate water filtration product for normalizing feed water quality.
Before proceeding with the installation, ensure there is enough space for the assembled system. If
using pressure tank, provide room for it as well. In case of shortage of space, pressure tank can be
removed to the distance of connecting tube length.
Install the reverse osmosis system in accordance with below procedure.

4.2. INSTALLATION

CAUTION! This product has been factory tested for leaks, and may contain residual moisture.
Before installation of tubing, filters, and membranes, wash your hands with antibacterial soap.
Ensure that the installation place is shielded from direct sunlight and removed from heating
appliances.