Download Print this page

Panasonic FX-550L Series Instruction Manual

Digital fiber sensor amplifier for io-link

Advertisement

Quick Links

Digital Fiber Sensor Amplifi er for IO-Link
FX-550L Series
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct and optimum
use of this product.
Kindly keep this manual in a convenient place for quick reference.
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
This product is not equipped with an automatic interference prevention function.
By setting diff erent frequencies, interference can be prevented for up to four units.
For the setting method, refer to <PRO3> in "
1
INTENDED PRODUCTS FOR CE MARKING
● This product complies with the following standards / regulations.
<EU Directive>
EMC Directive
2
PART DESCRIPTION
UP key
• Teaching
• Threshold value fi ne
adjustment
• Select setting items
Sensing output operation
Digital display (Green / Red)
indicator (Orange)
MODE indicator: L / D (Yellow)
・Lights when setting SENSING OUTPUT OPERATION MODE
MODE indicator: CUST (Yellow)
・Lights when setting LIGHT SENSITIVITY SETTING MODE
IO-Link communication indicator / MODE indicator
:PRO (Yellow) (Note)
Note
During IO-Link non communication
Normal status
Main unit PRO mode
Function
Lamp OFF
3
MOUNTING
How to mount
1. Fit the rear part of the mounting section of
the amplifi er on a DIN rail.
2. Press down the rear part of the mounting
section of the unit on the DIN rail and fi t the
front part of the mounting section to the DIN
rail.
How to remove
1. Push the amplifi er forward.
2. Lift up the front part of the amplifi er to remove
it.
How to connect the fi ber cable
● Mount the fi ber cables in the state power is not supplied.
● Be sure to fi t the attachment to the fi ber cables fi rst before inserting that to the
amplifier. For details, refer to the instruction manual enclosed with the fiber
cables.
● Insert the fi ber cables slowly into the inlets until they stops. Excessive force may
damage the product.
1. Snap the fiber lock lever down till it stops
completely.
2. Insert the fi ber cables slowly into the inlets
until they stops. (Note)
3. Return the fiber lock lever to the original
position till it stops.
Note: With the coaxial refl ective type fi ber, insert the single core fi ber cable into the beam-emitting inlet "P" and the
multi-core fi ber cable into the beam-receiving inlet.
If they are inserted in reverse, the sensing performance will deteriorate.
INSTRUCTION MANUAL
ME-FX551L No.0061-87V
WARNING
PRO MODE."
12
SET key
DOWN key
• Teaching
• Teaching
• Confi rm setting
• Threshold value fi ne
contents
adjustment
• Select setting items
MODE key
• Select modes
• Cancel during setting
During IO-Link communication
Normal status
Main unit PRO mode
Lights up
Flashes
Lights up
2. Press down
35mm width DIN rail
1. Push forward
2. Lift up
1. Snap
Fiber lock lever
Fiber for emitter
2. Insert
Fiber for receiver
4
WIRING
● When used as general-purpose sensor
(Brown / 1) +V
(White / 2) DO
(Black / 4) C/Q Note
(Blue / 3) 0V
<Terminal arrangement of M12 connector type>
1
4
2
3
Note: When the product is used as a general-purpose sensor, the IO-Link communication (C/Q) is generated in the
same way as control output (DO).
How to mount M12 connector
If the fixed ring loosens, the connector will come off, causing this product to
generate a communication error.
Before use, be sure to check that the fi xed ring is not loose.
● Firmly tighten the fi xed ring by rotating it.
5

LIST OF FUNCTIONS

Function
Teaching
Threshold value
Setting
Key lock function Set / Release
Output Operation
Setting
Light sensitivity
setting
Response time
setting
Timer setting
Timer time setting Timer time
Shift amount
setting
Shift threshold
valuet setting
Teaching lock
setting
Setting items in
digital display
setting
Time period hold
setting
Setting of digital
display turning
ECO Setting
Note: For the IO-Link communication setting, refer to the attached sheet, "Index List."(IMJE-FXLINDEX)
1. Fit
6

OPERATION PROCEDURE

The changed settings are not stored if turning the power OFF while setting.
Therefore, confi rm the settings by pressing the SET key before turning the power
OFF.
If settings are confi gured simultaneously on the main unit side and on the IO-Link
communication side, the settings that are applied last will be enabled.
● When turning ON the power, RUN mode is displayed and the digital display shows
the threshold value (green) and the incident light intensity (red).
<RUN mode>
<Sensing output operation mode>
3. Return
<Light sensitivity setting mode>
<PRO mode>
<RUN mode>
7
TEACHING MODE
Be sure that detection may become unstable depending on the use environment in
teaching if less margin is applied.
● Teaching can be set in RUN mode (And during IO-link communication).
● When connected to IO-Link master
+
24V DC
±10%
-
Load
Load
This product
Terminal No.
Terminal name
1
+V
2
Control output (DO)
3
0V
4
IO-Link communication (C/Q) Note
IO-Link communication setting
Setting on main unit
Function
(Note)
2-point teaching
Display
Index2
(SET Key)
adjustment setting
Limit-teaching
Reset setting
Index2
(UP Kye)
Limit-teaching
Emitting
Index2
(DOWN Kye)
frequency setting
Full-auto teaching
Index2
(SET Kye)
Emitting frequency
(Interference
Teaching cancel
Index2
revention setting)
Threshold value
Index60
Threshold value tracking
fine Adjustment
Cycle setting
Index12
Threshold value tracking
Light-ON/Dark-
Index61_1
Output Operation Setting
ON
Threshold value tracking
Light sensitivity
Index77
Storage cycle setting
select
Threshold value tracking
Selection from
Index66
Algorithm setting
4-mode
Preventive
Timer mode
Index64_1
maintenance threshold
Index64_2
value 1 setting
Amount select
Index74_1
Preventive
maintenance threshold
Shift threshold
Index74_2
value 2 setting
valuet
Preventive
Lock ON / OFF
Index85
maintenance
threshold value
Incident light
detection lag time
intensity / Displayed
Index83_1
setting
in percentage /
Operating time
Peak/bottom value
Number of data
Hold ON / OFF
Index83_2
save operations
Notification Flag
Turning ON / OFF Index82
Setting
Notification Event
FULL / ON / OFF Index80
Code
• Displays threshold value (green) and incident light intensity (red).
• Teaching, threshold value fi ne adjustment and key lock function can
be set.
• For setting method of each function, refer to "
"
8
THRESHOLD VALUE FINE ADJUSTMENT FUNCTION," or "
KEY LOCK FUNCTION."
• Select either Light-ON or Dark-ON.
• For the setting, refer to "
10
• The default setting is "
• Displays light sensitivity setting and enables its setting.
• For detailed information, refer to "
MODE."
• Detailed settings can be set for maximizing the performance of
individual functions.
• For setting items and setting method, refer to "
(Brown / 1) +V
+V
(White / 2) DO
DI
(Black / 4) C/Q
C/Q
(Blue / 3) 0V
0V
IO-Link master
• Recommended extension cable
Extension cable with connectors
on both ends
XS5W series
[OMRON Corporation]
Fixed ring
IO-Link communication setting
Setting on main unit
(Note)
Set / Release
Index2
Execution
Index2
Disabled / Interference
revention/Ambient
Index76_1
environment
sesistance
Selection from
Index76_2
4-mode
Cycle(time)
Index75_1
ON / OFF
Index75_2
Storage cycle
Index75_3
(each time)
Teaching mode
Index75_4
select
Index160
Index161
Index162
Index163
Index164
Index168
Index169
TEACHING MODE,"
7
9
SENSING OUTPUT OPERATION MODE."
" (Light-ON).
LIGHT SENSITIVITY SETTING
11
PRO MODE."
12

Advertisement

loading

Summary of Contents for Panasonic FX-550L Series

  • Page 1: List Of Functions

    (Black / 4) C/Q Note (Black / 4) C/Q Load Load Thank you very much for purchasing Panasonic products. (Blue / 3) 0V Please read this Instruction Manual carefully and thoroughly for the correct and optimum (Blue / 3) 0V...
  • Page 2 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION Useful when sensing object can be set ● Set the fine adjustment of threshold value in RUN mode (And during IO-link 2-point teaching This is basic teaching method. communication). Press down Press down <Thru-beam type> <Mirror refl...
  • Page 3 PRO MODE Notes: 1) Display of incident light intensity depends on the response time. Response time Incident light intensity ● When MODE indicator: PRO (yellow) lights up, PRO mode can be set (And during “ ” Max. 4,000 IO-link communication). “...
  • Page 4: Error Indication

    Non-volatile memory's lifetime. http://panasonic.net/id/pidsx/global Overseas Sales Division (Head Offi ce) 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 For sales network, please visit our website. PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2018...

This manual is also suitable for:

Fx-551l3-p-c2Fx-551l3-p-j