SECTION 3
Local codes including but not limited to AS/NZS 3000:2007 must be adhered to for all electrical work
and be undertaken by a licenced electrician. The electric element has a capacity of 2.4kW, paired with
a thermostat to control the water temperature of the tank. When the water temperature in the tank
reaches the normal setting 60°C, the thermostat will automatically disconnect & prevent overheating.
The thermostat has a unique internal fuse protection that is designed especially for Solar Hot Water
systems. The internal fuse is extra protection against any electrical malfunction & if the fuse activates,
the thermostat will need to be replaced. The Solar Thermostat has an auto-reset-over-temperature
cut-out for high solar contribution days & will automatically self-reset once the temperature drops
below the maximum setting of 70°C.
The iHeat storage tank has a dedicated port for entry into the electrical provision, this is clearly
marked by the supplied sticker on the external casing.
Installation Manual - Roof Mount Solar Hot Water - August 2017

Electrical Connections

Important
This drain hole shall
not be used as a cable
entry port. To do so will
void the warranty of
the system. Under no
circumstances shall the
drain hole be obstructed
or modified in anyway.
Incoming wiring shall be terminated as
per Australian Standards & weather-proof
cover shall be reinstalled after testing of
the circuit by qualified personal. Under no
circumstances shall the circuit be tested
under load without the system being full
of water.
Provision for approved
weather-proof
connection as per
Australian Standards
1300 829 118