SOL10+8-24G2 Series Solar & PoE Battery Charger USER’S MANUAL Mstronic Co., Ltd.
Page 2
User’s Manual SOL10+8-24G2-xxx Series Features: Dual Input, from solar panel and/or PoE (Solar First) to charge 24V battery, and another triple outputs: two PoE outputs on front and rear, terminal block on rear Built-in DC/DC converter, with various passive PoE output, 24V, 48V, 56V available.
Page 3
User’s Manual SOL10+8-24G2-xxx Series Panel Description Item Name Descriptions PoE power input indicator: the LED lights when the PoE input jack (the lower jack) POE : has 36V~57V input. Solar power input indicator: the LED lights when SOL terminal is connecting to a SOL : solar panel and the solar panel input voltage is over 24V.
Page 4
User’s Manual SOL10+8-24G2-xxx Series Operation Guide 1. Connect the battery to the BAT terminal. Make sure the polarities are correctly connected. Sequentially connect the solar panel to SOL terminal and connect POE source to PoE input (lower) jack. (If solar panel or PoE source is installed before the battery, and if the polarities of the battery be reversed, then the fuse will be burnt.) 2.
Page 5
User’s Manual SOL10+8-24G2-xxx Series 8. It can be two separate outputs on the rear panel, make sure the total draw is not over the limit. 9. The V- of PoE input, Solar input, and battery(-) are not the same grounding, must be properly isolated.
User’s Manual SOL10+8-24G2-xxx Series Electrical specifications 1. INPUT Two Input Source: A. Solar Panel : 30V~45V, B. POE : 36V~57V OUTPUT Output 1 Output 2 Output 3 Model No. (at rear terminal) (at front RJ45) (at rear RJ45) 24V/1.25A 24V/1.25A SOL10+8-24G1- 24V/10A (45+/78-)
Page 7
User’s Manual SOL10+8-24G2-xxx Series 3. Battery Charge Current: A. Solar Panel: depends on the solar panel, 10A max, B. POE: fixed current, 2.0A max 4. Battery Types: 24V Lead Acid Battery Protection: Battery Polarity Reverse Protection: If only battery connected to terminal, when the battery polarities were reversed, the model will stop output and REV indicator light When the battery be removed and re-connected to terminal, the function will be disable, if there is PoE power sources connected,...
User’s Manual SOL10+8-24G2-xxx Series Output Short Circuit Protection: When the rear output terminal or PoE output be short circuit, protection be active, the product stop output and auto-recover when the terminal back to normal connection. Battery Output Current Limit: The fuse will be burnt when battery output current over 10A Load Output Voltage Limit: The output voltage of the rear terminal is the same as battery.