Johansson 9733PL User Manual

Dcss/dscr multiswitch

Advertisement

Quick Links

User Manual
dCSS/dSCR Multiswitch
9733PL – 9734PL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9733PL and is the answer not in the manual?

Questions and answers

Summary of Contents for Johansson 9733PL

  • Page 1 User Manual dCSS/dSCR Multiswitch 9733PL – 9734PL...
  • Page 2: Table Of Contents

    Multiswitch (Ref. 9733PL & 9734PL) v1.0 ONTENTS 1. I ............3 NSTALLATION OF THE HARDWARE 1.1. Quattro LNB .................... 3 1.2. Wideband LNB’s ..................4 2. C ............5 ONFIGURATION OF THE MODULE 2.1. Input : Quattro versus Wideband ............... 5 2.2.
  • Page 3: Installation Of The Hardware

    Multiswitch (Ref. 9733PL & 9734PL) v1.0 1. I NSTALLATION OF THE HARDWARE 1.1. Quattro LNB...
  • Page 4: Wideband Lnb's

    Multiswitch (Ref. 9733PL & 9734PL) v1.0 1.2. Wideband LNB’s...
  • Page 5: Configuration Of The Module

    In this mode, a quad LNB can also be used, but then an extra product will need to set the 4 polarities of the LNB to match the VL – HL – VH – HH inputs of the 9733PL/9734PL. This can be done by using the Johansson ref 9930.
  • Page 6 Below is the relation between the STB tuned transponder and the wideband incoming transponder frequency. In both the Quattro and Wideband mode, the 9733PL/9734PL will allow powering the LNBs on both vertical trunks lines (see chapter 2.3 “DC Power” for more details on how to power the...
  • Page 7: Output: Legacy Versus Dscr

     The existing STBs will use UB1 through UB8  The new main STB will use UB1 through UB25 for 9733PL and UB1 through UB16 for 9734PL  In this case DiSEqC 1.0 and DiSEqC 2.0 will be used over the same cable from LNB to the apartment For an overview, please see the table in chapter 3: Technical Specifications.
  • Page 8: Dc Power

    A powersupply (Ref 2460) is designed to power up to 6 of these dSCR multiswitches in cascade. When connecting more than 6 dSCR multiswitches, it is adviced to add more powersupplies. Block diagram of the DC paths inside the 9734PL (the 9733PL is similar with only 1 STB output):...
  • Page 9: Technical Specifications

    Multiswitch (Ref. 9733PL & 9734PL) v1.0 3. T ECHNICAL PECIFICATIONS 9734PL 9733PL Trunk inputs Trunk outputs Trunk Frequency (MHz) 5 – 862 / 290 – 2340 STB Output Frequency (MHz) 5 – 862 / 950 – 2150 Trunk loss 2.5 / 2 dB...
  • Page 10 Multiswitch (Ref. 9733PL & 9734PL) v1.0 9733PL 9734PL EN50607 EN50494 EN50607 EN50494 FREQ FREQ FREQ FREQ 1210 1210 1210 1210 1420 1420 1420 1420 1680 1680 1680 1680 2040 2040 2040 2040 1028 1028 1028 1028 1072 1072 1072...
  • Page 11: Safety Instructions

    Multiswitch (Ref. 9733PL & 9734PL) v1.0 4. S AFETY NSTRUCTIONS Read these instructions carefully before connecting the unit To prevent fire, short circuit or shock hazard:  Do not expose the unit to rain or moisture.  Install the unit in a dry location without infiltration or condensation of water.
  • Page 12: Conditions Of Warranty

    Multiswitch (Ref. 9733PL & 9734PL) v1.0 5. C ONDITIONS OF WARRANTY Unitron N.V. warrants the product as being free from defects in material and workmanship for a period of 24 months starting from the date of production indicated on it.