The temperature sensor must be installed in a socket as near as possible to the collector outlet. Make sure that the sen-
sor makes good contact with the socket. Materials (sensor, cables, seals and insulation) used to install the temperature
sensor must be able to withstand high temperatures (up to 300°C).
REGOLATORE
SOLAR
SOLARE
REGULATOR
1 - Solar collector
2 - Storage cylinder
3 - Collector probe
4 - Disconnect valves
5 - Non-return valve
6 - Temperature gauge
7 - Vent valve
8 - Safety valve
9 - Pressure gauge
10 - Drain
11 - Expansion vessel
1
R
18
2
17

LOCATION OF PROBES

15
16
1
M
3
4
6
5
12
13
14
Gruppo idraulico
Water system
12 - Pump
13 - Flow regulator
14 - Flow meter
15 - Vent cock
16 - Manual bleed valve (accessory)
17 - Storage cylinder bottom probe
18 - Storage cylinder top probe
19 - Heat transfer fluid recovery
M - Collector outlet
R - Collector return
8
7
9
10
M
19
11
°C
4
4
GENERAL
11