Page 3
AXCALL How to use the door intercom. When a visitor comes to the entrance, he dials # and your telephone number (or presses the button with your name, if a ADI-623-08 is connected). Answer you telephone. During the call you will hear a beep every 5:th second to indicate that the call comes from the entrance.
Page 4
AXCALL AXCALL DI-623-21L 1. INTRODUCTION Axcall DI-623-21L is a door intercom to be connected to a company’s internal switch- board. This makes it possible to get in contact with all telephones from the entrance. A person can talk to the visitor at the entrance and also open the door. The door intercom also has a codelock function, which can be used by none-visitors.
AXCALL A separate button connected to terminal PL1:6 could even activate memory address 101 to get you in touch with the reception. Note! If the red LED starts flashing when you make a call, you have forgotten to connect the telephone line or the line is occupied. It’s also possible to make a call to the entrance.
Page 6
AXCALL 3. PROGRAMMING OF TELEPHONE NUMBERS* AND CODES * Only if direct buttons (ADI-623-08) or PL1:6 are to be used DI-623-21L has the possibility to store 99 codes and/or telephone numbers. These are stored at fixed addresses, 101 to 199, and could be 1 to 14 digits. You should make a log of what is stored at which address.
Page 7
AXCALL Example 2: Program a code (# 154) with 4 digits (5678) which should be disabled if PL2:15 PL2:16 is closed. (2). - Enter your password. - Press # 154 5678# 1 2 - Press *. The unit returns to working mode. If you enter more codes you only have to press * when the programming is finished, and not after each code.
Page 8
AXCALL Enter time of call in seconds (default value 60 sec.). - Enter your password. You will hear a beep every second. - Press # 53 double beep < 01-99> and you hear two short and one long. - Press *. The unit returns to working mode. Ex: # 53 60 = 60 seconds Enter time of call in minutes.
AXCALL 7. PROGRAMMING OF UNIT-ID If you have more than one door unit the printer outputs can be connected in parallel to one printer or PC. To be able to know to which unit the printout belongs, you must give all units a unique number. This is done in the following way: - Enter your password.
AXCALL Installed by Company: ............ Name: ............Telephone: ..........Password: ....10. ADDITIONAL PROGRAMMING Besides what’s earlier mentioned in this manual, there are two functions that could be reprogrammed. The short beep that comes every 5:th second can be disabled, and the line test during calling can also be disabled.
Page 11
AXCALL SHORT FORM PROGRAMMING GUIDE FOR DI-623-21L TELEPHONE NUMBER*/CODES CLEAR only if DI-608 or PL1:6 is used PASSWORD MEMORY Enter Delete RST-button RST-button Password Password 199200 # 6-digit code # # 101-199 # 101-199 OPENING 1-14 digits # TIME Function Password PRINTOUT # 51(sec)53(min)
Page 12
AXCALL CONNECTION OF DI-623-21L Power supply Electric lock Disable Intercom answering Telephone line Normally in position A. Tamper ON OFF 9 10 Connector for prox reader. See manuals for each control unit. Voltage jumper 15 16 171819 20 21 22 23 24 Connection of DI-608 Speaker...
Page 13
AXCALL CONNECTION OF DIRECT BUTTONS WITH ADI-623-08 As mentioned in the introduction you can connect one or more ADI-623-08 to a DI- 623-21L to be able to use more direct buttons. The connection is made with the cable that comes with the ADI-623-08. To light the name labels you also have to connect power on PL1:1 &...
Page 14
AXCALL LIST OF NUMBERS/CODES IN DI-623-21L...