GE GUD27ESSMWW Technical Service Manual page 73

24 and 27 in. unitized laundry centers
Table of Contents

Advertisement

Fault
Code Fault Name
23
Critical Lid Lock
Failure
24
Lid Logic Failure
25
Pressure Sensor
Dropout
26
Out of Balance
(OOB) Ended Final
Spin
Description
1. Lock blockage
2. Lid Lock failure. Will not lock or unlock or
is locked while lid is opened.
Lid switch failure. This fault is set if the
system perceives the lid to be both OPEN
and LOCKED for 5 consecutive seconds.
1. Disconnected pressure hose.
2. Pressure tube is pinched or has water in
it.
3. Pressure sensor failure.
Washer could not redistribute load to
eliminate OOB condition to achieve final
targeted spin speed.
– 73 –
Repair Action
Verify that the lid lock is not
blocked by any external debris.
Check lid switch continuity at
J513 on the control.
Check continuity of lid lock
position. Opened or Closed.
Check for proper operation
of lid lock. 120 VAC while
activating
Check lid lock wiring harness
from the control to lock
assembly.
1. Check harness and
connections from the control
to the lid lock assembly for
damage and continuity.
2. Run a spin cycle. Pull up on
the lid during spin for more
than 5 seconds and see if this
fault occurs. Replace lid lock
assembly.
Check pressure tube for
pinches where it goes through
top cover grommet.
Check pressure tube for
trapped water.
Check water valve operation
and for any leaking water
valves.
Check home water pressure.
Check the output voltage from
the pressure sensor to ensure
it matches the water level in
the basket according to the
pressure sensor chart.
Ensure pressure chamber port
is free from obstruction using
drill bit size 1/16" by hand so
as not to drill through the inner
wall.
Manually rebalance the load,
check basket for damage, and
run a Drain & Spin cycle.
If washer spins properly, talk
with consumer about loading.
If the washer will not spin
properly, check the balance
ring, the rod and spring
assemblies, the speed sensor,
and the speed sensor harness
for proper operation.
Check if the unit is stable and
leveled.

Hide quick links:

Advertisement

Table of Contents
loading