User Manual
RC-19 Single-Use Temperature Data Logger
Overview
The temperature data logger is mainly used for monitoring and logging temperature in storage and shipment of food and pharmaceuticals, such as cooler
boxes, refrigerated trucks, containers, etc.
The logger can connect to a computer via its USB port and export a PDF report. It features an internal sensor and a CR2450 lithium battery with whole
protection grade up to IP67. A barcode is prepared for scanning.
Illustration
Waterproof plastic bag
USB port
Button(Start/Status/Mark/Stop)
Configuration Info
LED indicator
Barcode label
Technical Parameters
All the parameters are preconfigured before the logger leaves the factory. Some can be customized based on your needs.
Temperature measuring range:
Alarm threshold:
default (customizable)
Storage temperature:
-30℃~70℃
Data interface:
USB2.0
Temperature accuracy:
0.5℃/0.9℉(-20℃~40℃); 1℃/1.8℉(others)
Report type:
PDF format
Sensor type:
internal NTC
Battery:
built-in CR2450 wide temperature lithium battery
Note: It is suggested storing the logger at room temperature before started.
Parameter Instructions
Memory capacity:
16000 points at maximum. Actual record capacity may be different due to different log cycles.
Start delay:
When the logger is started, it delays for a period of time to start logging. The delay time can be customized.
Alarm thresholds:
Alarm zone can be set according to the alarm thresholds. The logger supports three upper limit and two lower limit.
H3
H2
H1
L1
L2
Alarm type:
Single
Cumulative
Alarm delay:
The logger does not alarm immediately when the temperature is within the alarm zone. It begins to alarm only when the alarm delay time elapses.
Operating Instructions
Press and hold the button for 5 seconds to
start logging. Green LED will flash 5 times.
Front
Note: The picture is for reference only. Any discrepancy in future, please adhere to the final product.
-30℃~70℃ Resolution: 0.1℃
The range of value greater than H3 is the super high temperature alarm zone 3
The range of value greater than H2 is the super high temperature alarm zone 2
The range of value greater than H1 is the super high temperature alarm zone 1
The range of value less than L1 is the super low temperature alarm zone 1
The range of value less than L2 is the super low temperature alarm zone 2
The logger records the single time for continuous out-of-limit events
The data logger records the cumulative time of all the out-of-limit events
Start/Stop Info
Mark Info
Status Request
Paste Area
Memory capacity:
16000 points (MAX)
Battery life:
2 years
(stored and used under normal temperature environment)
Log cycle:
6, 15, 30, 60, 90, 120, 180days (customizable)
Protection grade:
IP67
Size:
80mm (L) x 48mm (W) x 5.8mm (H)
Alarm type:
single or cumulative
Weight:
approx. 15g
Peel off the barcode label for further use.
Back

Advertisement

loading

Summary of Contents for Elitech RC-19

  • Page 1 User Manual RC-19 Single-Use Temperature Data Logger Overview The temperature data logger is mainly used for monitoring and logging temperature in storage and shipment of food and pharmaceuticals, such as cooler boxes, refrigerated trucks, containers, etc. The logger can connect to a computer via its USB port and export a PDF report. It features an internal sensor and a CR2450 lithium battery with whole protection grade up to IP67.