Summary of Contents for Delfin VapoMeter SWL5

  • Page 1 VapoMeter SWL5 User Manual www.delfintech.com...
  • Page 2: Table Of Contents

    ONTENTS ........................... 3 NTRODUCTION ..........................3 PPLICATIONS ......................4 ONTENTS OF PACKAGE ......................4 EASUREMENT PRINCIPLE ....................5 SER INTERFACE DESCRIPTION ......................5 PERATING INSTRUCTIONS ................... 8 SETTINGS AND INFORMATION MENU ......... 10 ECOMMENDATIONS FOR MEASUREMENTS WITH THE ETER ......................... 12 AINTENANCE ........................
  • Page 4: Introduction

    ELFIN ETER NTRODUCTION Thank you for purchasing the Delfin VapoMeter. You have chosen the ideal device for measuring transepidermal water loss (TEWL) or water loss from different surfaces. The VapoMeter uses a closed chamber measurement principle and thus measurements are unaffected by ambient airflows. The short measurement time ensures that blocking of normal evaporation is minimal.
  • Page 5: Contents Of Package

    ONTENTS OF PACKAGE SWL5001 Accessories VapoMeter unit Delfin Modular Core (DMC) software 2 standard adapters Receiver unit 2 small adapters Additional standard adapters 2 batteries Additional small adapters...
  • Page 6: User Interface Description

    VapoMeter SWL5 User Manual 1.3 10.11.2016 SER INTERFACE DESCRIPTION 1. Operating button 2. PC connection indicator 3. Battery indicator 4. Main display 5. Three past values PERATING INSTRUCTIONS The VapoMeter is ready for operation after stabilisation to ambient relative humidity and temperature.
  • Page 7 1. Switch the power on by pressing the black operating button. Check that the correct adapter mode is selected (USE STANDARD/SMALL ADAPTER, see ‘Settings and information menu /Adapter). Press the button once again to start operation. Wait for 3 seconds’ countdown combined with three short tones before skin contact, which is indicated by a long tone and a message ONTO SKIN.
  • Page 8 VapoMeter SWL5 User Manual 1.3 10.11.2016 4. The VapoMeter is ready for the next measurement when the measurement chamber has been ventilated. The latest TEWL reading and the message VENTILATE with a progressing bar alternates on the display until ventilation is finished. A new measurement can be performed when the message PRESS TO MEASURE is displayed.
  • Page 9: Settings And Information Menu

    always one of these adapters with the corresponding measurement mode to obtain reliable TEWL and TOWL (transonychial water loss) values. Pull the adapter out of place and press the new one straight and tightly into the opening without twisting. NOTE: If special in-vitro adapters are used, check from the package label or the manufacturer which measurement mode should be used with the selected in-vitro adapter.
  • Page 10 Turns the PC connection OFF or ON. A wireless connection to the computer can be used only when the receiver unit is connected to the PC, the Delfin Modular Core (DMC) software is running and the PC mode of the VapoMeter is ON.
  • Page 11: Recommendations For Measurements With The Vapo Meter

    ECOMMENDATIONS FOR MEASUREMENTS WITH THE ETER The VapoMeter produces reliable results when the person-related, environmental and instrument-related variables are controlled. The person-related and environmental variables affect the absolute water loss. The instrument-related variables affect the measured water loss value. Guidelines for TEWL measurements (references 1-3 on page 12) are useful for controlling the person-related and environmental variables, but the instrument-related variables do not apply to the closed chamber method.
  • Page 12 VapoMeter SWL5 User Manual 1.3 10.11.2016 Adapters The VapoMeter has been calibrated with the standard and the small adapters. The measured values are reliable only when using one of these adapters with the corresponding adapter mode. Person-related and environmental variables This list contains only selected variables.
  • Page 13: Maintenance

    3. Skin Pharmacol Appl Skin Physiol 2001;14:117-128. Vera Rogiers and the EEMCO Group: EEMCO Guidance for the assessment of transepidermal water loss in cosmetic sciences. AINTENANCE Store the VapoMeter in its case, in a clean and dry place. The storage temperature and relative humidity should be close to operating conditions.
  • Page 14 VapoMeter SWL5 User Manual 1.3 10.11.2016 3. Insert the new batteries to match the (+) and (-) signs in the battery case. Incorrect insertion of batteries may damage the device. Do not use rechargeable batteries. Paristojen virheellinen asennus voi vahingoittaa laitetta.
  • Page 16: Technical Data

    VapoMeter SWL5 User Manual 1.3 10.11.2016 ECHNICAL DATA System components • VapoMeter measuring unit • 2 standard (Ø 11 mm) and 2 small (Ø 4.5 mm) adapters • User manual • Carrying case Accessories • DMC data collection software • Receiver unit •...
  • Page 17 • Recommended ambient conditions Relative humidity Operating range 5% to 80% Storage 5% to 80% Temperature Operating range +15 °C to +35 °C • Two-year guarantee Storage +5 °C to +35 °C Bluetooth module certifications • Contains FCC ID: QOQBLE113 •...
  • Page 18: Appendix A: Display Messages

    VapoMeter SWL5 User Manual 1.3 10.11.2016 PPENDIX ISPLAY MESSAGES Message Explanation USE STANDARD/ Check that a corresponding adapter is in use. SMALL ADAPTER PRESS TO MEASURE Instrument is ready to measure. Press the operating button to proceed. . 3, 2, 1 (timer before Prepare to place the VapoMeter on the skin.
  • Page 20: Appendix B: Troubleshooting

    VapoMeter SWL5 User Manual 1.3 10.11.2016 PPENDIX ROUBLESHOOTING Problem Before requesting repair check the following: VapoMeter fails to start The batteries may be low. Change the batteries. or complete a measurement. VapoMeter fails to Remove and replace the batteries to reset the “power-down”.
  • Page 21 “Ready to record…”. • Restart DMC software. Note that this VapoMeter SWL5 model is not compatible with DelfWin 4 software (or any earlier software version) due to different wireless technology. Delfin Modular Core (DMC) is the only compatible...
  • Page 22: Appendix C: Guarantee

    The VapoMeter comes with a two (2) year guarantee from the date of purchase from Delfin Technologies Ltd or an authorized distributor. During the guarantee period a faulty device will be repaired or replaced free of charge by Delfin Technologies Ltd. The guarantee covers raw materials and manufacturing faults. Batteries are excluded from this guarantee.