  • Page 1 USER MANUAL 1.10 DC1000 Dialog-Controller Basic, Prime, Compact, Clean...
  • Page 2 This equipment manual is only complete in conjunction with the product-related hardware and software user  Completeness manuals required for the individual application. You can reach us at: Berghof Automation GmbH Harretstr. 1 72800 Eningen Germany T +49.7121.894-0 F +49.7121.894-100 e-mail: controls@berghof.com www.berghof.com Berghof Automation GmbH works in accordance with DIN EN ISO 9001:2000.
  • Page 3 Transition into new CD. New corporate name “Berghof Automation GmbH”. Update of chapter “Extension modules”. 1.10 03.05.2016 New EMC directive. Correction standards. Update of chapter “Chemical resistance”. Update of section “Nameplate”. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx...
  • Page 4 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER Blank page Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx...
  • Page 5: Table Of Contents

    Technical data DC1012 ........................38 2.7.1. DC1012 Front view ..........................40 2.7.2. DC1012 Rear view ..........................40 2.7.3. DC1012 Dimensions .......................... 41 2.7.4. DC1012 Panel cutout ......................... 42 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx...
  • Page 6 4.1.3. Analog inputs ............................. 81 4.1.4. Digital inputs/outputs 12/4/8-0.5 ......................82 4.1.5. Digital inputs, positive switched ......................83 4.1.6. Digital outputs, positive switched......................86 4.1.7. Digital input/output pin assignments ....................89 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx...
  • Page 7 Maintenance/Upkeep ........................139 8.3. Repairs/Service ..........................139 8.3.1. Warranty ............................139 8.4. Nameplate ............................140 Nameplate descriptions (example) ....................140 8.5. Addresses and Bibliography ......................141 8.5.1. Addresses ............................141 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx...
  • Page 8 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER 8.5.2. Standards/Bibliography ........................142 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx...
  • Page 9: General

    The manual contains information about the following topics  Areas of application  Safety  Mechanical construction  Electrical construction  Connections  Commissioning Care and maintenance  Decommissioning  Disposal  Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100106FE05.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 10: Hazard Categories And Terminology

    Failure to observe the information indicated by this warning may result in injury or property damage. NOTICE No hazard Information indicated in this manner provides additional notes concerning the product. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100106FE05.docx...
  • Page 11: Qualified Personnel

    Dialog Controller is employed are complied with.  that the users always have available all relevant information they require with regard to the Dialog Controller and its employment. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100106FE05.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 12: Basic Safety Measures

    This can result in death, serious injury or extensive property damage. Only open the housing cover once the Dialog Controller has been safely dis- HAZARDOUS connected from the power supply. VOLTAGE Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100106FE05.docx...
  • Page 13: Use As Prescribed

    All types of failure and the associated fuse systems are to be taken into ac- count at system level. The advice of the SPC manufacturer should be sought if necessary. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100106FE05.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 14: Conformity Declaration

    With connected contact line system the compliance of the EMC requirements on the complete system must be checked and ensured („fixed installation“ for the purpose of the EMC directive). Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100106FE05.docx...
  • Page 15: Transport And Setup

    When installing the Dialog Controller, take particular care to ensure that the included seal profiles are not damaged. Also ensure compliance with the ambient conditions specified under “Technical specifications”. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100106FE05.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 16 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER Blank page Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100106FE05.docx...
  • Page 17: Product Description

    RS232 and an RS485 port. E-bus extension The Dialog-Controller’s I/O level can be expanded via the E-bus socket to include up to seven E-bus sub- scribers. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 18 MMC/SD card slot  The scope of supply of the controller module consists of:  Scope of supply  Dialog-Controller DC10xx incl. 2-pin plug-in connector for power supply Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 19: Identification

    = Touchpanel CLEAN = Continuous of the Resolution = Keyboard front foil sheeting = Touch + Keyboard V = VGA 640 x 480 = compact model 2VF100227DG04.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 20: The Different Versions Of The Dialog-Controller

    Communication is the forte of the DC1000. Its spectrum of interfaces and exten-  Prime Interface sion options makes is the reason for this. The DC1000 with a Prime interface is extremely adaptable. The maximum scope of the interfaces can be supplemented with further commu- nication an I/O extension cards.
  • Page 21: Overview Of Types

    DC1005M T grey Clean Basic 2.2.4. Variable thanks to extension cards The DC1000 can be fitted with a maximum of three extension cards. The spectrum encompasses pure I/O cards as well as communication cards, which are already installed by Berghof.
  • Page 22: Dialog-Controller Dc1005 / Dc1010 / Dc1012 Construction

    Keyboard Display Front FRONT Controller Grafik Flash +24 V BASIS 2VF100233DG01.cdr No potential isolation of the CAN and RS485 interface on the Basic Interface NOTICE version. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 23: Technical Data Dc1005

    EN 61000-6-4, industrial environments Interference resistance EN 61000-6-2, industrial environments Protection class Insulating resistance EN 61131-2; DC 500 V test voltage Protection type IP20 (front: IP65) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 24 3 slots for 3 I/O modules or 2 I/O modules and one AnyBus module (Prime Interface only) Further features Yes, battery backed. Real-time clock SD card 1 SD card slot or RS232 (X5) (Prime Interface only) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 25: Dc1005 Front View

    USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER 2.4.1. DC1005 Front view LED (red) optional controlled by application Power Status-LED Front-USB 2VF100229DG01.cdr 2.4.2. DC1005 Rear view Cover interface boards Connections Frontpanel 2VF100230DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 26: Dc1005 Dimensions

    Freiraum / clearance > 20 mm All dimensions in [mm] max. 52 Freie Luftzirkulation free air circulation DC1005C T Freiraum / clearance > 20 mm DC1005T T 2VF100234DG03.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 27: Dc1005 Panel Cutout

    It must therefore be installed vertically and the upper and lower housing aper- tures must not be covered over! DANGER OF OVERHEATING AND FIRE! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 28: Technical Data Dc1010

    EN 61000-6-4, industrial environments Interference resistance EN 61000-6-2, industrial environments Protection class Insulating resistance EN 61131-2; DC 500 V test voltage Protection type IP20 (front: IP65) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 29 3 slots for 3 I/O modules or 2 I/O modules and one AnyBus module (Prime Interface only) Further features Yes, battery backed. Real-time clock SD card 1 SD card slot or RS232 (X5) (Prime Interface only) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 30: Dc1010 Front View

    USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER 2.5.1. DC1010 Front view Front-USB 2VF100241DG01.cdr 2.5.2. DC1010 Rear view Cover interface boards Connections Frontpanel 2VF100242DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 31: Dc1010 Dimensions

    PgUp BkSp PgDn Alle Maße in [mm] / All dimensions in [mm] Freie Luftzirkulation DC1010T K free air circulation Freiraum / clearance > 20 mm 2VF100243DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 32: Dc1010 Panel Cutout

    It must therefore be installed vertically and the upper and lower housing aper- DANGER OF tures must not be covered over! OVERHEATING AND FIRE! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 33: Technical Data Dc1010 Compact (Cp)

    EN 61000-6-4, industrial environments Interference resistance EN 61000-6-2, industrial environments Protection class Insulating resistance EN 61131-2; DC 500 V test voltage Protection type IP20 (front: IP65) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 34 3 slots for 3 I/O modules or 2 I/O modules and one AnyBus module (Prime Interface only) Further features Yes, battery backed. Real-time clock SD card 1 SD card slot or RS232 (X5) (Prime Interface only) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 35: Dc1010 Compact (Cp) Front View

    USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER 2.6.1. DC1010 Compact (CP) front view LED (red) optional controlled by application 2VF100459DG00.cdr 2.6.2. DC1010 Compact (CP) rear view Cover interface boards Connections Frontpanel 2VF100460DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 36: Dc1010 Compact (Cp) Dimensions

    2.6.3. DC1010 Compact (CP) dimensions max. 77 Alle Maße in [mm] / All dimensions in [mm] DC1010T T Freie Luftzirkulation free air circulation Freiraum / clearance > 20 mm 2VF100461DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 37: Dc1010 Compact (Cp) Panel Cutout

    It must therefore be installed vertically and the upper and lower housing aper- tures must not be covered over! DANGER OF OVERHEATING AND FIRE! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 38: Technical Data Dc1012

    EN 61000-6-4, industrial environments Interference resistance EN 61000-6-2, industrial environments Protection class Insulating resistance EN 61131-2; DC 500 V test voltage Protection type IP20 (front: IP65) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 39 3 slots for 3 I/O modules or 2 I/O modules and one AnyBus module Further features Yes, battery backed. Real-time clock SD card 1 SD card slot or RS232 (X5) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 40: Dc1012 Front View

    USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER 2.7.1. DC1012 Front view Front-USB 2VF100272DG01.cdr 2.7.2. DC1012 Rear view Cover interface boards Connections Frontpanel 2VF100242DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 41: Dc1012 Dimensions

    PgUp BkSp PgDn Alle Maße in [mm] / All dimensions in [mm] Freie Luftzirkulation DC1012T K free air circulation Freiraum / clearance > 20 mm 2VF100270DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 42: Dc1012 Panel Cutout

    It must therefore be installed vertically and the upper and lower housing aper- DANGER OF tures must not be covered over! OVERHEATING AND FIRE! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 43: Technical Data Dc1012 Compact (Cp)

    EN 61000-6-4, industrial environments Interference resistance EN 61000-6-2, industrial environments Protection class Insulating resistance EN 61131-2; DC 500 V test voltage Protection type IP20 (front: IP65) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 44 3 slots for 3 I/O modules or 2 I/O modules and one AnyBus module Further features Yes, battery backed. Real-time clock SD card 1 SD card slot or RS232 (X5) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 45: Dc1012 Compact (Cp) Front View

    USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER 2.8.1. DC1012 Compact (CP) front view 2VF100473DG01.cdr 2.8.2. DC1012 Compact (CP) rear view Cover interface boards Frontpanel Connections 2VF100242DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 46: Dc1012 Compact (Cp) Dimensions

    77 Alle Maße in [mm] / All dimensions in [mm] DC1012T T CP Freie Luftzirkulation free air circulation Freiraum / clearance > 20 mm 2VF100474DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 47: Dc1012 Compact (Cp) Panel Cutout

    It must therefore be installed vertically and the upper and lower housing aper- tures must not be covered over! DANGER OF OVERHEATING AND FIRE! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 48: Mounting And Connection

    (PE) with a copper cross-section of at least 1.5 mm². The Dialog-Controller is equipped with a 6.3 x 0.8 mm plug-in tab for this purpose. 2VF100236DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 49: Pin Assignment

    The onboard 10/100 Base-T Ethernet adapter with an RJ45 connector is used to connect the unit to a net- work. The “LNK” and “RCV” status LEDs provide information regarding a successful network link. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 50: Usb

    Based on the variety and number of available USB chip and USB drive manufactures, there is no guar- antee that every available USB drive on the market works with the device. Every USB drive has to be Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 51: Can Bus

    NC (Do not connect) CAN_L CAN_GND NC (Do not connect) Sub-D9 M NC (Do not connect) NC (Do not connect) CAN_H NC (Do not connect) NC (Do not connect) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 52: Serial Ports

    NC (Do not connect) NC (Do not connect) Sub-D9 F NC (Do not connect) NC (Do not connect) NC (Do not connect) NC (Do not connect) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 53 The interface is terminated “softly” in the Dialog-Controller at 500 Ω (older devices 5 kΩ ). A 120 Ω differen- tial terminating resistor can be activated for each S4 switch. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 54 An attenuating connection, for example via 200 Ω at multi-ple points on the bus. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 55: E-Bus

    Always hold a lead by the plug when connecting or disconnecting a device. Never pull on the lead itself! The connection level for all external devices is located on the rear of the Dialog-Controller. All connections are plug-in. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100107FE10.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 56: Sd Card

    At present data memory cards with a memory capacity of up to 1 GB can be used. 2VF100312DG01.cdr If the SD card reader is activated, then the second RS232 interface (X5) is not NOTICE longer available. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100107FE10.docx...
  • Page 57: Dialog-Controller Operation

    Dialog-Controller.  CP1131-P: PLC programming using CODESYS and Berghof Target Support Package  CPC++: C programming directly on the LINUX operating system Status-LED Ethernet Status-LED 2VF100232DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 58   perform a controller reset; or alternatively: Mode selection switch / Service menu / CODESYS/ web browser  return the controller to operation Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 59: Service Menu

    Up to two lines reflecting the current PLC status can be displayed. Line 1 will always be visible, while line 2 will only appear when an error occurs. Parameter window PLC window 2VF100273DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 60: Using The Service Menu

    Info to display the hardware and software version levels as well as diagnostic data; and it also offers the save function (USB, SD, Flash). Display to adjust contrast values.  Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 61: Config" Service Menu

    New settings will only take effect after a restart! The “EXIT” button allows you to leave the menu without saving any changes which may have been made. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 62 The “EXIT” button allows you to leave the menu without saving any changes which may have been made. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 63 PPP: TCP/IP over PPP protocol PG Tool: CODESYS can upload and debug serial pro- grams CNW: reserved RTC: Setting the battery-buffered realtime clock.  CLOCK “RTC” Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 64: Plc" Service Menu

    Acknowledgement of the RESET COLD command. As soon as the “CONTINUE” button is pressed the PLC program and all variables, including the RETAIN variab- les, are reset. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 65: Info" Service Menu

    PLC program usb0: the first USB to be plugged in (a maximum of 8 sticks can be plugged in via a USB hub). Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 66: Display" Service Menu

    (although such changes will remain in effect until the next restart). Dialog-Controllers with monochrome displays: The contrast can be adjusted here. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 67: Plc Window

    PLC ERROR STOP Operating mode selection switch S1 is set to the RUN position. However, the PLC program could not be started due to an error. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 68 E-bus modu- les. Once the number of actually available E-bus modules agrees with the controller configuration setting, the controller can be restarted using a reset command. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 69 “Reboot” button. Note: The diagnostic data must definitely be saved prior to re- booting because only at this time can all the important data be saved! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 70: Decommissioning

    All electronic components such as PCBs, drives, etc. must be set aside and disposed of separately. Disposal is generally regulated by national and local ordinances which must be complied with. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 71: Maintenance

    The Dialog-Controller fails to Memory fault. Return the device for service. completely boot. Corrupted software. Put the device in the configuration mode and reload the firmware. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 72 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER Blank page Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx...
  • Page 73: Extension Modules

    I/O card with SC-CAN U DC XS 12/8/4-CSC PROFIBUS master DC Profibus-DPM PROFIBUS slave DC Profibus-DPS PROFIBUS master/slave DC Profibus-DPV I/O card, analog/digital DCXR01 I/O card, digital DCXR02 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 74: I/O Card With Sc-Can Interface

    Connection for a 5-place 7-segment display with remote control receiver The scope of supply of the control module consists of:  Scope of supply  I/O card installed in the Dialog-Controller Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 75: Technical Data

    4 (X2) Output current 0.5 A Short circuit protection Potential isolation Connection technique Standing front wiring for 3.81 terminal strips (not part of the standard deli- very) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 76 Standing front wiring for 3.81 terminal strips (not part of the standard deli- very) Operating and display elements Display elements Interface (X11) for 5-place, 7-segment display with IR receiver diode for remote control Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 77: Pin Assignment

    8 A (depending on the number of I/Os). External power supply The CAN communications interface is supplied from the Dialog-Controller’s power supply. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 78 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER The I/O card is factory installed and may only be installed in the Dialog-Controller in the position shown in  Installation the figure below. 2VF100306DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 79 SC_CAN. Termination The SC_CAN must be terminated at both line ends. The values for these terminating resistors deviate from the ISO 11898 (CAN bus) standard and they can be ordered separately from Berghof (CTR-SC-T2, part no.: 201601200). CAUTION If the SC_CAN bus is incorrectly terminated, its operation can result in...
  • Page 80  External 7-segment display the I/O subassembly. Connection is to connector X11 by means of a cable available from Berghof. The exter- nal display can be addressed from the software in the same way as the digital I/Os. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com...
  • Page 81: Analog Inputs

    The maximum value will be indicated if no sensor is connected to an analog input. NOTICE Shield support in switchgear cabinet is urgently recommended for rea- sons of EMC! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 82: Digital Inputs/Outputs 12/4/8-0.5

    I/O group. - A2 IN 1-8 IN 9-12 I/O 13-16 SC-Test 7Seg/IR OUT 1-8 1 2 3 4 5 6 2VF100307DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 83: Digital Inputs, Positive Switched

    (filtering) can be activated in individual groups of 32 inputs. This function is only available for C applications. The sampling rate is prede- NOTICE fined under IEC 61131-3.  Basic input circuit diagram 2VF100009DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 84 Potential isolation Yes (optocoupler) in groups Status indicator None Alarms Definable depending on the software Input delay Definable via the software Input capacitance < 10 nF Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 85 Limits for “0” signal for the “OFF” condition 5.5 V Upper voltage limit max. 1.5 mA Upper current limit max. Lower voltage limit min. 0 mA Lower current limit min. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 86: Digital Outputs, Positive Switched

    The LED is on when the associated output is activated, that is, when it is logical “1” (HIGH).  Basic output circuit diagram 2VF100011DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 87 Prohibited Insulation resistance Reference voltage 0 V < U < 50 V Test voltage up to an altitude of 2000 m DC 500 V Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 88 Therefore, this state should be avoided! The output will again be operational once the overload has been corrected and the unit has cooled down. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 89: Digital Input/Output Pin Assignments

    Digital OUT +24 V OUT4 Digital OUT +24 V OUT5 Digital OUT +24 V OUT6 Digital OUT +24 V OUT7 Digital OUT +24 V OUT8 Digital OUT +24 V Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 90 Encoder 2 IN 3 (X1) IN 4 (X1) The encoder values are only reset (0) when the unit is switched on or rebooted after a reset. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 91: Profibus-Master Card

    Potential isolated PROFIBUS-MASTER RS485 interface with integrated DC/DC converter and opto- couplers  Cyclic DP-Master services The scope of supply consists of:  Scope of supply  PROFIBUS-MASTER card installed in the Dialog-Controller Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 92: Technical Data

    1 PROFIBUS-MASTER DP interface for connecting a max. of 125 slave faces nodes Potential isolation Connection technique 9-pin, Sub-D Operating and display elements Display elements 4 diagnostic LEDs Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 93: Front View And Pin Assignment

    The PROFIBUS-MASTER communications interface is supplied from the Dialog-Controller's power supply. Installation The PROFIBUS-MASTER card is factory installed and may only be installed in the Dialog-Controller in the position shown in the figure below. 2VF100309DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 94 RS232 signal RS232 signal N.C. Do not connect Bus ground N.C. Do not connect N.C. Do not connect N.C. Do not connect N.C. Do not connect Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 95 The baud rate is set in the CODESYS controller configuration. GSD file The PROFIBUS-MASTER module is integrated in the CODESYS controller configuration with a GSD file. As of Version 1.10.0, this GSD file will be part of the Berghof Target installation package. Indicator LEDs Indica-...
  • Page 96: Profibus-Slave Card

    All required DP services as well as user parameter data and device-specific diagnostics The scope of supply consists of:  Scope of supply  PROFIBUS-SLAVE card installed in the Dialog-Controller Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 97: Technical Data

    Potential isolation Connection technique 9-pin, Sub-D Operating and display elements Display elements 4 diagnostic LEDs Address switch Switches not used for applications Termination Switchable terminating resistor Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 98: Front View And Pin Assignment

    The PROFIBUS-SLAVE communications interface is supplied from the Dialog-Controller's power supply. Installation The PROFIBUS-SLAVE card is factory installed and may only be installed in the Dialog-Controller in the po- sition shown in the figure below. 2VF100311DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 99 GSD file The PROFIBUS-SLAVE module is integrated in the CODESYS controller configuration with a GSD file. As of Version 1.10.0, this GSD file will be part of the Berghof Target installation package. Indicator LEDs Four diagnostic LEDs indicate the current operating state and any error messages.
  • Page 100 Red, flashing at 2 Hz: Missing user parameter; initialized data length does not match configuration Red, flashing at 4 Hz: Initialization error in the ASIC Off: No diagnostic data available Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 101: Profibus Card (Master/Slave Functionality)

    Potential isolated PROFIBUS RS485 interface with integrated DC/DC converter and optocouplers Cyclic DP master services  The scope of supply consists of:  Scope of supply  PROFIBUS card installed in the Dialog-Controller Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 102: Technical Data

    1 PROFIBUS DP Master interface and 1 PROFIBUS DP Slave interface faces for connecting 125 Slave nodes max. Potential isolation Connection technique 9-pin, Sub-D Operating and display elements Termination Via dip switch or configuration file Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 103: Front View And Pin Assignment

    The PROFIBUS card is factory installed and may only be installed in the Dialog-Controller in the position shown in the figure below. State Reset Profibus T ermination DC Profibus-DPV 2VF100405DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 104 DPSlave.gsd: GSD file for the PROFIBUS Master which can access the card configured as a  PROFIBUS Slave All application and diagnostic data are set up via the CODESYS controller con- NOTICE figuration or are provided by the application. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 105 DP Slave not yet correctly addressed by DP Master Green 4x flashing Watchdog error If the watchdog is active the connection to the Master has been lost. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 106: I/O Xr01 And Xr02 Cards With Analog And Digital I/O

    The digital inputs (X2) can also be used as counters. 2VF100468DG00.cdr The scope of supply of the controller module consists of:  Scope of supply  max. 3 XR I/O cards installed in the Dialog-Controller Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 107: Technical Data

    4 analog ±10 V or ±20 mA inputs/outputs Resolution Min. 16 bit Connection technique Standing front wiring for terminal strips (not part of the scope of supply) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 108: Pin Assignment

    “IO_VALID” does not become valid again until the controller has been restart- ed. Therefore, it is necessary to constantly monitor “IO_VALID” in the PLC pro- gram. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 109: Plug-In Connectors

    Makes it easier to connect the shield or GND line  15420 BL-I/O 3.5/10F SW Without LED for analog channels (X3 and X4)  Single-wire connection Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 110: Installation

    The inputs are transferred internally to the core of the CPU in cycles. An open input is inter- preted as static 0 (LOW). Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 111 If there is a risk of lightning impact, please consult the manufacturer. Load nominal voltage L+ DC 24 V (SELV) Polarity reversal protection Potential isolation Status display Yes, green LED per input on the plug-in connector. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 112 Limits for “0” signal for the “OFF” condition 5.0 V Upper voltage limit max. 0.8 mA Upper current limit max. Lower voltage limit min. 0 mA Lower current limit min. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 113 If thermal loads occur owing to energetic recovery L(SCr) or fast de-excitation, the overload protection may react prematurely even in the case of outputs which are not involved. off(SC) 2VF100392DG01.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 114 The output stage is protected against overload, which must be taken into ac- count for high inrush currents from lamps, for example. Principal output circuit diagram, positive-switching + 24 V OUT (IN) 2VF100465DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 115 0.5 A Total current of all outputs max. 2 A Two outputs switched in parallel for logic link permissible for increased output permissible up to 1 A Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 116: Terminal Assignment Of Digital Inputs/Outputs

    Digital IN +24 V Counter input +24 V Encoder 4 A/up IN16 Digital IN +24 V Counter input +24 V Encoder 4 B/down GND I/O supply Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 117: Analog Inputs/Outputs

    Voltage transmitter Connector AO-U ±10 V AO-U AO-U AO-U AO-U AO-U4 ±10 V AO-U4 AO-U4 AO-U4 AO-U4 Current transmitter Connector AO-I ±20 mA AO-I AO-I AO-I AO-I Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 118 Filter rate and If the scanning rate is above 1 ms the digital filtering ensures constant value scanning rate curves instead of delivering the same value repeatedly. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 119 60 dB (direct current); 20 dB at 50 Hz Dynamic characteristics Greatest temporary differential 1.5 % of the measuring range during electrical interference test in compliance with IEC 61131-2 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 120 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER Typical example of external connections 2VF100469DG02.cdr CAUTION The module is damaged at input voltages of more than ±14 V. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 121 Dynamic characteristics (refer also to Dynamic characteristics of the analog inputs) Greatest temporary differential 1.5 % of the measuring range during electrical interference test in compliance with IEC 61131-2 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 122 Calibration to maintain the 12 months accuracy class Greatest temporary differential ±1.5 % of the measuring range during electrical interference test in compliance with IEC 61131-2 Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 123 > 500 Ω Load impedance range Overload protection Short-circuit proof. Current limitation at around 24 mA. Interruption for 300 ms. Cyclical reattempt. Typical example of external connections 2VF100471DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 124 A+ to A- > 300 kΩ During booting routine The analog output is not yet active during the booting routine of the DC1000. of the DC1000 Differences to zero value when switched on and off is around < 2 %.
  • Page 125 32 bit Real (24 bit payload) program General characteristics Permissible load types Load to AGND Greatest inductive load 0.1 mH 0…500 Ω Load impedance range Typical example of external connections 2VF100472DG00.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100124FE08.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 126 The voltage between A+ and A- can be displayed if the analog input is confi-gured as AI-U. A- must be connected to AGND for the sensor to be monitored. Readjustment is not required because it is readjusted internally. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100124FE08.docx...
  • Page 127: Maintenance

    All connections are correct and secure; The ground wire (PE) is properly connected.  NOTICE Be sure all covers on the Dialog-Controller are closed before returning the unit to service! Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100109FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 128: Real-Time Clock With Backup Battery

    Replace batteries only with batteries which have the same rating! EXPLOSION HAZARD Make sure the battery is facing the right way when installed. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100109FE04.docx...
  • Page 129: Battery Replacement

    Push the old battery out to the side, can be accessed from above.  Insert the new battery from the side. Check for correct polarity and battery type. 2VF100269DG03.cdr Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100109FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 130 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER Blank page Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100109FE04.docx...
  • Page 131: Chemical Resistance

    Cleansers (Fantastic, Formula 409, Joy, etc.) Isopropyl alcohol Vinegar Hexane Coffee Turpentine Naphtha Grease Lead-free gasoline Cooking oil Diesel oil Salt Motor oil Transmission fluid Antifreeze Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100123FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 132: Resistance Of The Autotex Front Foil Sheeting To Chemicals

    < 30 % Paraffin Alkali carbonate Castor oil Bichromate Silicone oil Potassium ferrocyani- Turpentine oil replacements Brake fluid Acetonitril Decon Sodium bisulfate Aircraft fuel Gasoline Water Salt water Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100123FE04.docx...
  • Page 133: Resistance To Household Chemicals

    Low humidity (< 10 % rel.H.): 85 °C Outdoor use As is the case for all polyester-based sheeting, AUTOTEX is not intended for extended exposure to direct sunlight. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100123FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 134: Resistance Of The Autoflex- Front Foil Sheeting To Chemicals

    Concentrated mineral acids  Concentrated alkaline solutions   Benzyl alcohol SURFACE  Methyl alcohol RESISTANCE  High pressure steam above 100 °C Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100123FE04.docx...
  • Page 135: Resistance To Household Chemicals

     Ketchup  Lemon juice 6.3.3. Outdoor use As is the case for all polyester-based sheeting, AUTOTEX is not intended for extended exposure to direct sunlight. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100123FE04.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 136 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER Blank page Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100123FE04.docx...
  • Page 137: Copyright And Software Licenses

     FTL, refer to free-type license (FTL)  When required, the source code for the free software can be requested from Berghof within three years after delivery at cost price. The exact address for this: Berghof Automation GmbH Harretstrasse 1 72800 Eningen (Germany) The licenses used by Berghof are listed in the ‘Copyright and software licens-...
  • Page 138 USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER Blank page Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100170FE01.docx...
  • Page 139: Annex

    Sold under statutory warranty conditions. Warranty lapses in the event of unauthorised attempts to repair the equipment and/or product, or in the event of any other form of intervention. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100055FE06.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 140: Nameplate

    Identification no. (item no. + serial no.) Customer no. Supply voltage Manufacturer’s address Mac addresses Production date QR code (identification no.) CE marking Brand of the manufacturer (trademark) Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100055FE06.docx...
  • Page 141: Addresses And Bibliography

    D-90482 Nuremberg / Germany info@ethercat.org www.ethercat.org Beuth Verlag GmbH, 10772 Berlin  DIN-EN Standards VDE-Verlag GmbH, 10625 Berlin VDE Verlag GmbH, 10625 Berlin  IEC Standards Internet search: www.iec.ch Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100055FE06.docx | DC1000_HB_en_2D0982010ZD00.docx...
  • Page 142 CiA users' or- ganisation. Notice: Our Technical Support team will be glad to provide other literature references on request. Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com DC1000_HB_en_2D0982010ZD00.docx | 2VF100055FE06.docx...

Table of Contents