Hispacold Ecomaster Comfort MH-083 Manual page 17

Table of Contents

Advertisement

MESSAGE
23
PCHN
24
WTR
25
CMP
26
FP
27
PV2
28
PV1
29
PS1
30
PS2
31
C1
32
PV3
33
PRV
34
PHV
35
PRC
36
RB
37
LB
38
CB
39
PRVN
40
PHVN
41
FPN
42
RPRV
43
RPHV
44
MDFV
45
MDHV
46
MPRV
47
MPHV
Warning codes:
Message
1
POT?
2
RAD
3
DFBN
4
RH
5
PRBN
6
PLBN
7
CBN
8
LPD
9
HPD
10
LPP
11
HPP
MH-083 Ecomaster Comfort user manual
DESCRIPTION
Short or Open circuit in the passenger's channel sensor
Short or Open circuit in the water sensor (passenger)
Short circuit at compressor output (passenger)
Short circuit at recirculation pump output (passenger)
Short circuit at ON/OFF evaporator output speed 2(passenger)
Short circuit at ON/OFF evaporator output speed 1(passenger)
Short circuit at stair heater blower output speed 1 (passenger)
Short circuit at stair heater blower output speed 2 (passenger)
Short circuit at ON/OFF condensor output (passenger)
Short circuit at ON/OFF evaporator output speed 3(passenger)
Short circuit in the roof valve output (passengers)
Short circuit in the floor valve output (passenger)
Short circuit at passenger recirculation flap output (passenger)
Short circuit at right evaporator fans output (passengers)
Short circuit at left evaporator fans output (passengers)
Short circuit at condensor fans output (passenger)
The roof valve was previously detected but now it is not detected (passenger)
The floor valve was previously detected but now it is not detected (passenger)
The recirculation pump was previously detected but now it is not detected (passenger)
The return of the roof valve is missing (passenger)
The return of the floor valve missing (passenger)
Motorised defogger valve without return position
Motorised additional heater valve without return position
Motorised roof valve without return position
Motorised floor valve without return position
Description
Inconsistency between POT selected and configuration detected
Short or Open in radiation sensor (driver)
No charge in defroster fans PWM (passengers)
Short or Open in humidity sensor (passengers)
No charge in right evaporator fans PWM (passengers)
No charge in left evaporator fans PWM (passengers)
No charge in condenser fans PWM (passengers)
Low pressure error (Driver zone)
High pressure error (Driver zone)
Low pressure error (Passenger zone)
High pressure error (Passenger zone)