Item
Condition
28. Courtesy
1) Channel: 3 (Center)
Tone
Wide/Narrow: Analog Wide
Deviation
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
29. TD
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 3kHz
De-emp: OFF
Detector: +peak, –peak
AG setting
: 0.1kHz/0.5Vp-p (177mVrms)
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
30. Transmit
1) Channel: 3 (Center)
Audio Input
Wide/Narrow: Analog Wide
(TA)
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
AG setting
: 1kHz/280mVrms
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
31. BPF
1) Tracking generator
Output: –20dBm
Spectrum analyzer
Frequency: Desired frequency
Span: 50MHz
32 MCF
1) Wide
Tracking generator
Output: –20dBm
Spectrum analyzer
Frequency: 49.95MHz
Span: 100kHz
2) Narrow
Spectrum analyzer
Span: 50kHz
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
CONTROL
AG
I/O jack
DVM
TD (pin 8)
Deviation
Rear
TX ANT
meter
CONTROL
AG
I/O jack TA
DVM
(pin 9)
Tracking
Rear
RX ANT
RX
generator
Spectrum
RX
CN41
analyzer
Tracking
Rear
CN46
RX
generator
Spectrum
RX
CN47
analyzer
NXR-800
Adjustment
Parts
Method
PC
±1.00kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±0.50kHz
±0.05kHz
PC
±0.75kHz
±0.02kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±0.75kHz
±0.02kHz
PC
±3.00kHz
±0.03kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±1.50kHz
±0.02kHz
L132
Adjust it by the pro-
Refer to Fig. 1. (Page 34)
L133
grammed frequency
L134
to look like the wave
L135
in fi gure 1.
L74
Adjust it to look like
Refer to Fig. 2. (Page 34)
L90
the wave in fi gure 2.
L75
Adjust it to look like
Refer to Fig. 3. (Page 34)
L91
the wave in fi gure 3.