NXR-800
Alignment
Item
Condition
1. Setting
1) Connect the DC power output to the rear panel DC terminal (13.8V).
2) Connect the front panel COM port (D-sub 9 connector) to the PC serial port with a cross-wired cable.
3) Activate the FPU to go to the test mode.
2. Temperature
1) Receive unit (Celsius or
Sensor
Fahrenheit)
2) Transmit unit (Celsius or
Fahrenheit)
3. Driver
1) Low
Amplifi er
2) Center
Power
3) High
(Pre ADJ)
4. RF Power
1) High
Down
2) Low
Detection
5. VCTCXO
1) REF Low
Lock Voltage
SSG frequency: 10MHz
–10ppm (9.99999MHz)
SSG output: 0dBm
2) REF High
SSG frequency: 10MHz
+10ppm (10.00001MHz)
SSG output: 0dBm
3) MOD Low
SSG frequency: 10MHz
–10ppm (9.99999MHz)
SSG output: 0dBm
4) MOD High
SSG frequency: 10MHz
+10ppm (10.00001MHz)
SSG output: 0dBm
6. Transmit
1) A: Low
VCO Lock
Voltage
(Adjustment)
2) B: Low
7. Receive
1) A: Low
VCO Lock
Voltage
(Adjustment)
2) B: Low
36
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Ther-
Room
RX
mometer
temper-
ature
TX
SSG
TX
REF IN
DVM
REF CV
(CN401)
REF IN
MB_CV1
(CN303)
DVM
TX
CV
TX
DVM
RX
CV1
RX
Adjustment
Parts
Method
PC
Measuring room
ADJ
temperature, write
the value with PC.
PC
Value: 1
Fixed value writing
ADJ
PC
Value: 1
Fixed value writing
ADJ
Check
1.5V or more
3.5V or less
1.5V or more
3.5V or less
L128
Adjust the interval of
the L128.
1.35~1.55V
L108
Adjust the interval of
the L108.
1.35~1.55V
L28
Adjust the interval of
Make the adjustments after
the L28.
inserting the insulating tube
1.30~1.35V
in the L28 and L30 coils and
applying the high frequency
varnish.
L30
Adjust the interval of
the L30.
1.50~1.55V
Specifi cations / Remarks