Kenwood NXR-800 Service Manual page 40

Uhf digital base-repeater
Hide thumbs Also See for NXR-800:
Table of Contents

Advertisement

NXR-800
Item
Condition
24. DQT
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 3kHz
De-emp: OFF
Detector: Peak hold
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
25. CW ID
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
26. Test Tone
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
27. DTMF
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
40
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Adjustment
Parts
Method
PC
±0.75kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±0.35kHz
±0.05kHz
PC
±2.00kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±1.00kHz
±0.05kHz
PC
±3.00kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±1.50kHz
±0.05kHz
PC
±2.85kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±1.50kHz
±0.05kHz
Specifi cations / Remarks