Operating instructions
Safety sensor
1.6 Warning about misuse
In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded when safety switchgear is
used. The relevant requirements of the standard ISO 14119
must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden;
the manufacturer shall accept no liability for damages resulting from
such invasive work, arbitrary repairs, conversions and/or modifications
to the device.

2. Product description

2.1 Ordering code
This operating instructions manual applies to the following types:
BNS 300-01ZG-
-
No.
Option
Description
connecting cable
ST
integrated connector
2211
increased switching distance
2230
supplementary signalling output
2334
increased switching distance and
supplementary signalling output
2246
U
42 VAC
e
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Destination and use
The safety sensor is designed for application in safety circuits and is
used for monitoring the position of movable safety guards to ISO 14119
and IEC 60947-5-3. To actuate the safety sensors, only the BPS 300,
BPS 303 or BPS 303 SS actuators can be used, conventional magnets
are not suitable.
The safety switchgears are classified according to
ISO 14119 as type 4 switching devices.
The safety switches are used for applications, in which the hazardous
situation is terminated without delay when the safety guard is opened.
Only the entire system consisting of the safety sensor (BNS 300 with
integrated safety-monitoring module) and the actuator (BPS 300/
BPS 303 or BPS 303 SS) meets the requirements of the standard
IEC 60947-5-3.
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
The entire concept of the control system, in which the
safety component is integrated, must be validated to the
relevant standards.
2
2.4 Technical data
Standards:
Enclosure:
Tightening torque:
Protection class:
Degree of pollution:
Termination:
- ordering suffix -2230:
Operating principle:
Actuator:
Coding level according to ISO 14119:
Switching distances:
- Assured switching distance s
- Assured switch-off distance s
Operating voltage:
Operating current:
Rated impulse withstand voltage U
Rated insulation voltage U
:
i
Required short-circuit current:
Output:
Switching voltage:
Load current:
Switching capacity:
Max. fuse rating:
Supplementary signalling contact:
Ambient temperature:
Storage and transport temperature:
Max. switching frequency:
Resistance to shock:
Resistance to vibration:
EMC rating:
2.5 Safety classification
Standards:
Intended structure:
- 1-channel usage:
for max. 5 million of switching cycles / year for
sensor and for MTTF
B
value for safety contact:
10d
- at 100% contact load:
- at 80% contact load:
- at 60% contact load:
- at 40% contact load:
- at 20% contact load:
Service life:
B
10d
n
MTTF
d
0,1 x n
op
(Determined values can vary depending on the application-specific
parameters h
, d
and t
op
op
cycle
EN
BNS 300
IEC 60947-5-3, BG-GS-ET-14
glass-fibre reinforced thermoplastic
max. 300 Ncm, A/F 36
IP67 to IEC 60529
cable Boflex 4 x 0.75 mm²,
connector M12 x 1, 4-pole;
cable YSLYÖ-0 5 x 0.75 mm²
BPS 300, BPS 303, BPS 303 SS, coded
:
ao
8 mm (ordering suffix -2211/-2334)
:
ar
18 mm (ordering suffix -2211/-2334)
24 VDC +10 %/–15 %
ordering suffix -2246: 42 VAC
:
imp
250 VAC / 30 VDC
1 enabling path
max. 250 VAC
max. 750 VA
3 A gG D-fuse to IEC 60269-1
max. 100 mA
−25 °C ... +55 °C
−25 °C ... +70 °C
30 g / 11 ms
10 ... 55 Hz, amplitude 1 mm
according to EN 61000-6-2
ISO 13849-1
useable to cat.1 / PL c
≥ 40 years for safety contact
d
d
x
x
3600
s/h
h
op
op
op
t
cycle
as well as the load.)
3
magnetic
low
5 mm,
15 mm,
30 mA
4 kV
100 A
max. 3 A
5 Hz
400,000
1,000,000
2,500,000
7,500,000
20,000,000
20 years