1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3 Axial misalignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Encontrará el manual de
ES
instrucciones actual en su
idioma oficial de la UE en nu-
estra página de Internet www.
schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
ufficiale UE) è scaricabile in
Internet all'indirizzo www.
schmersal.net.
1 About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version
in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional informa-
tion.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be
found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet: www.
schmersal.net.
The information contained in this operating instructions manual is provi-
ded without liability. Subject to technical modifications.
If multiple safety components are wired in series, the Perfor-
mance Level to EN ISO 13849-1 will be reduced due to the
restricted error detection under certain circumstances.
The entire concept of the control system, in which the safety
component is integrated, must be validated to EN ISO 13849-
2.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
BNS 16
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BNS 16 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal BNS 16

  • Page 1: Table Of Contents

    3.3 Axial misalignment ........3 Further technical information can be found in the Schmersal Electrical connection catalogues or in the online catalogue on the Internet: www.
  • Page 2: Warning About Misuse

    25,000,000 Service life TM 20 years 2.3 Destination and use The BNS 16 safety sensor is designed for application in safety circuits 3600 and is used for monitoring the position of movable safety guards to EN MTTF 0,1 x n 1088 and EN 60947-5-3.
  • Page 3: Dimensions

    The proper functionality must always be checked by means of the connected safety-monitoring module. Actuating planes BNS 16 Actuating planes BNS 16 LR 4 Electrical connection 4.1 General information for electrical connection The electrical connection may only be carried out by autho- rised personnel in a de-energised condition.
  • Page 4: Set-Up And Maintenance

    Operating instructions Safety sensor BNS 16 5 Set-up and maintenance 6 Disassembly and disposal 5.1 Functional testing 6.1 Disassembly The safety function of the safety components must be tested. The The safety switchgear must be disassembled in a de-energised condi- following conditions must be previously checked and met: tion only.
  • Page 5: Appendix

    Person authorized for the compilation of the Ulrich Loss technical documentation: Möddinghofe 30 42279 Wuppertal Place and date of issue: Wuppertal, July 22, 2009 Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloa- ded from the internet at www.schmersal.net.
  • Page 6 K. A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Telefon +49 - (0)2 02 - 64 74 - 0 Telefax +49 - (0)2 02 - 64 74 - 1 00 E-Mail: info@schmersal.com...

Table of Contents