24
WETROOM MEMBRANE
14
15
16
17
The concrete surface should
be prepared with a concrete
primer to seal the surface and
provide better adhesion.
NB: the steel surface of the
drain unit must not be
primed/prepared.
Cut the reinforcing tape to the
required length.
Remember to clean the steel
surface before applying the
membrane.
NB: always follow the
wetroom supplier's
specific recommendations for
use.
Reinforcing tape should be
fitted around all 4 sides of the
drain unit and layed/sealed
onto the wetroom membrane.
NB: wetroom membrane
and reinforcing tape should
overlap by at least 40 mm.
[EN1253]
A proper wetroom membrane
with full coverage is always
recommended whatever the
floor construction.
NB: the relevant national
wetroom rules and
the wetroom supplier's
specific recommendations
should always be followed as
a minimum.
TILE FRAME
18
19
20
UK
ClassicLine tile frame
with rubber gasket is
75 mm high overall.
Shown here with ClassicLine
Column grating.
The tile frame should be
trimmed to fit the tile thickness
including adhesive = tile layer*
Groove 2
Groove 2 = 6 - 8 mm *tile layer
Groove 3 = 10 - 12 mm *tile layer
Groove 4 = 14 - 16 mm *tile layer
Groove 5 = 18 - 20 mm *tile layer
etc.
The gasket should be fitted to
the frame after cutting to the
correct length/height.