A cycle has to consist of at least two clock duty times and one clock pause
time.
IMPORTANT
The total sum of clock duty times and clock pause times is the duty time. If
the clock duty time and the clock pause time are selected in a way that
their total sum cannot correspond to the duty time, the duty time is auto-
matically rounded up.
Example:
IMPORTANT
Clock duty time = 5 sec., Clock pause time = 3 sec., selected duty time =
11 sec.
→ The duty time is rounded up to 5+3+5 = 13 sec.

8 Maintenance / Service

Please observe the safety regulations in chapter 2 when servicing
the device.
IMPORTANT
If the timer is continually subjected to atmospheric influences the seal in the cover
and the electric lines should be regularly checked (at least every 6 months) for signs
of porosity.
All other parts are maintenance-free.

9 Troubleshooting

ATTENTION:
Troubleshooting of AP 117 electronic timers should only be conducted
by an authorized specialist.
DANGER
Fault
Phase interruption
Supply voltage too
Timer does
low
not start
Cable wires have
been connected po-
larity-reversed
Timer fails
Voltage drop under
when operat-
load
ing in „RUN"
Possible causes
Troubleshooting
Check fuses and con-
nection cables
Check supply voltage
and cables
Check polarity
Check supply connec-
tion
15
Remedy
Replace fuse or
connection cable
Use correct supply
voltage
Connect cable
wires with correct
polarity
Use correct supply
voltage