78W WALL MOUNT INSTALLATION INSTRUCTIONS
TM
Thank you for buying RAB lighting fi xtures.
Our goal is to design the best quality
products to get the job done right. We'd like
to hear your comments. Call the Marketing
Department at 888-RAB-1000, or email:
marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper
grounding is required for safety. This product must be installed in accordance with the applicable installation code by a
person familiar with the construction and operation of the product and the hazards involved.
Make certain power is OFF before installing or maintaining fi xture. No user servicable parts
WARNING:
inside.
MOUNTING ARM ON FIXTURE
1. Remove the Arm Cover from the Arm.
2. Feed wires from Fixture through Gasket into Arm.
3. Line up Arm and Fixture. Place fl at washers, lock
washers and nuts on the 3/8-16" bolts inside the Arm
and tighten securely to housing.
4. Make sure the Gasket is secure between Arm and
Fixture.
MOUNTING FIXTURE ON WALL
1. Separate Wall Mount Cover and Wall Mount Box.
2. Orient box so that "TOP" is on top.
3. Secure Wall Mount Box to a sturdy wall. Use
appropriate mounting hardware such as lag bolts and
anchors with washers suitable for the mounting sur-
face. Use weatherproof silicone sealant between wall
and Wall Mount Box.
4. Feed supply wires through Wall Mount Box, Gasket,
and Wall Mount Cover.
5. Check that Gasket between Wall Mount Box and
Wall Mount Cover is secure and screw the cover on
box using four screws.
6. Line up Arm and Wall Mount Cover. Place fl at wash-
ers, lock washers and 3/8-16 bolts from wall bracket
(do not use long bolts provided with Arm), inside the
Arm and tighten securely.
7. Feed wires through the Arm Gasket into Arm. Make
necessary connections in the Arm.
8. Replace the Arm Cover. Be sure Gasket on Arm
Cover is in place.
9. Tighten Close Up Plugs and apply weatherproof
silicone sealant to all unused conduit entry points.
Also use sealant between the wall and Wall
Mount Box.
®
Plugs
Arm Cover
Arm Gasket
3/8-16 bolts
Arm
Gasket
Plugs
Page 1
.
Fixture
Gasket
Screws
3/8" bolts
Wall Mount
Cover
Gasket
Wall Mount Box
Tether
Arm
Plugs (4)

Advertisement

loading

Summary of Contents for RAB Lighting WPLED 78W series

  • Page 1 ® WPLED 78W WALL MOUNT INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fi xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com...
  • Page 2: Troubleshooting

    ® WPLED 78W WALL MOUNT INSTALLATION INSTRUCTIONS WALL MOUNT BOX DETAILS WIRING Universal voltage driver permits operation at 120 to 4.57” 277VAC, 50 or 60Hz. Key Hole Slot 1. Connect the black fi xture lead to the (+) LINE supply lead. 2.4”...
  • Page 3 ® WPLED 78W WALL MOUNT INSTALLATION INSTRUCTIONS WPLED2T78 Cool WPLED3T78 Cool WPLED4T78 Cool WPLED2T78 Neutral WPLED3T78 Neutral WPLED4T78 Neutral Page 3 WPLED78 IN 1011...

This manual is also suitable for:

Wpled2t78 coolWpled3t78 coolWpled4t78 coolWpled2t78 neutralWpled4t78 neutralWpled3t78 neutral