Technical Data; Safety; Safety Instructions - Sinclair Duro Operating Manual

Floor stripper
Table of Contents

Advertisement

1.0 Technical data/technical description
Power supply
Power consumption
Number of strokes
Sound pressure level
Sound energy level
Hand/Arm-Vibration
Weight
Comes with

2.0 Safety

The Sinclair Duro® Stripper has Class 2 protective insulation. It meets the
following safety specifications:
DIN VDE 0740
IEC 745,
The machine has radio interference suppression to the standards:
76/889/EWG,
EN 55014

3.0 Safety Instructions

Disconnect the power supply before any maintenance is carried out.
Use only recommended blades and make sure the blade is sharp before starting.
Maintenance should be undertaken only by qualified personnel. Use only genuine
Sinclair parts.
Transport
Always remove the blade before transporting the machine.
CAUTION!!! Always wear ear and eye protectors! CAUTION!!!
Using this machine without ear and eye protectors may jeopardize or harm your
health. It may harm especially your ears and increase the risk of an accident.
PLEASE READ DETAILED SAFETY INSTRUCTIONS ON COLORED
SHEET BEFORE USING MACHINE!
3.1 Introduction
This operating manual should be used to receive the maximum benefit from
your Duro® Stripper. Following these instructions will both extend the life of
your machine and reduce repair costs.
120V AC
2000W, 18A
with current limitor
8500 strokes/min
88 dB(A)
101 dB(A)
16 m/s2
35 lbs
Duro® Stripper, 2 rigid blades, safety
goggles and tool kit. Case is optional.
CENELEC HD 400,
VBG 7j (National spec)
87/308/EWG
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents