TPLP
ELECTRIC DEFROST MODELS - SINGLE EVAPORATOR 10A MAX.
NOTES
1). USE COPPER CONDUCTORS ONLY
2). USE 75°C WIRE (OR HIGHER)
3). OVERCURRENT PROTECTION FOR
EVAPORATOR FAN MOTORS AND
DEFROST HEATERS MUST NOT EXCEED
MAXIMUM VALUE SHOWN ON
EVAPORATOR NAMEPLATE.
4.) MAY BE FACTORY INSTALLED-MOUNTED
AND WIRED ON EVAPORATOR
2-LP ED 12/07
T30-TPLP-PDI-14
WIRING DIAGRAM - 208-230/1/60
STANDARD PSC MOTORS
FOR ALL MODELS WITHOUT DEFROST HEATER CONTACTOR
USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION
REFER TO EVAPORATOR
NAMEPLATE FOR ELECTRICAL
DEFROST CLOCK
PARAGON # 8145
OR EQUIVALENT
TM
3
4
X
1
2
N
COMPR INTERLOCK
PUMP DOWN
SWITCH
(IF USED)
4
F
X
BN
DT
GND.
BK
FD
DEFROST TERMINATION
& FAN DELAY
CONTROL
(10.0A MAX.)
DT-DEFROST TERM
FD-FAN DELAY
FAN
FAN
MTR
MTR
1
2
REQUIREMENTS
L1
L2
GND
FUSE OR
15A
CIRCUIT
BREAKER
(IF USED)
SPACE
THERMOSTAT
NOTE #4
N.C.
LIQUID LINE
SOL VALVE
NOTE #4
N
H1
3
1
C
RD
YL
WH
HEATER
LIMIT
SWITCH
(10.0A MAX.)
DEFROST HEATERS
FAN MOTOR
POWER PLUGS
EVAPORATOR
REFER TO
FAN
EVAPORATOR
MTR
DATA PLATE FOR
6
MOTOR QUANTITY
TERMINALS
-COMPONENT TERMINAL
-TERMINAL BLOCK TERMINAL
CONDUCTORS/WIRING
ALL FIELD WIRING MUST BE DONE IN
COMPLIANCE WITH ALL APPLICABLE LOCAL
AND NATIONAL CODES.
- 10 -
WARNING
EVAP FIELD MODIFICATION
MUST BE MADE
SEE NOTE:
1
RELOCATE WHITE WIRE FROM
N TO H1 AS SHOWN
2
INSTALL ORANGE JUMPER
(SUPPLIED LOOSE)
FROM H2 TO N
2
ORANGE JUMPER
H2
H3
FACTORY WIRING
WIRING BY OTHERS
OPTIONAL FACTORY
OR BY OTHERS
PSC
60Hz
29/11/18