HPE FlexFabric 5950 Series Installation Manual page 16

Hide thumbs Also See for FlexFabric 5950 Series:
Table of Contents

Advertisement

To attach the mounting bracket to the middle mounting position:
1.
Place the wide flange of a mounting bracket against the chassis side panel. Align the slide rail
installation holes with the screw holes at the middle mounting position.
2.
Use M4 screws to secure the mounting bracket to the switch.
3.
Perform the same steps to attach another mounting bracket to the other side of the switch.
Figure 15 Attaching the mounting bracket to the middle mounting position (power module
side at the front)
Connecting the grounding cable to the switch
For more information, see
Installing the switch in the rack
1.
Wear an ESD wrist strap and make sure the strap makes good skin contact and is reliably
grounded.
2.
Determine the switch installation position in the rack. Attach cage nuts to the square holes in the
rack post.
3.
Verify that the mounting brackets have been attached to the two sides of the switch.
4.
One person supports the bottom of the switch and moves the switch to the planned installation
position in the rack.
5.
Another person uses screws (user-supplied) to attach the mounting brackets to the rack.
"Connecting the grounding cable to the
12
chassis."