Powerhead Break-In
Use the diagnostics software to start break-in oil-
ing after a powerhead rebuild. The break-in oiling
program runs for two hours of outboard operation,
above 2000 RPM.
1
1. Break-in oil setting
Tiller/Remote Programming
This feature con trols the start in ge ar prot ection
function of the neutral switch. Tiller operated mod-
els, including remote models with an installed tiller
conversion kit, MUST be set to TILLER.
1. Starter mode setting
ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS
Ignition Timing
Use the Ignition Timing scre en to check an
adjust EMM timing. EMM timing must be synchro-
nized to crankshaft position.
Refer to TIMING ADJUSTMENTS on p. 113.
008580
Check timing af ter any of the following proce-
dures:
Powerhead replacement
•
Crankshaft replacement
•
Flywheel removal or replacement
•
CPS replacement
•
1
EMM replacement
•
EMM software replacement
•
IMPORTANT:
set and the outboard reaches operating tempera-
ture before making adjustments.
008580
Make sure the timing poin ter is
d
4
008572
67