Connections & Pinouts
XLR4 - Power input
Pin 1
=
GND
Pin 2
=
Data A (RS485)
Pin 3
=
Data B (RS485)
Pin 4
=
+12v
XLR3 - Data Output
Pin 1
=
GND
Pin 2
=
Data A (RS485)
Pin 3
=
Data B (RS485)
Hirose 4 - Cascade output
Pin 1
=
GND
Pin 2
=
Data A (RS485)
Pin 3
=
Data B (RS485)
Pin 4
=
+12v
9 pin Dsub - Tally inputs
Pin 1
=
Cam 1 - Tally input (hold to GND for Tally ON)
Pin 2
=
Cam 1 - Touch Down output. Open collector to GND**
Pin 3
=
Cam 2 - Tally input (hold to GND for Tally ON)
Pin 4
=
Cam 2 - Touch Down output. Open collector to GND**
Pin 5
=
Cam 3 - Tally input (hold to GND for Tally ON)
Pin 6
=
Cam 3 - Touch Down output. Open collector to GND**
Pin 7
=
Cam 4 - Tally input (hold to GND for Tally ON)
Pin 8
=
Cam 4 - Touch Down output. Open collector to GND**
Pin 9
=
Common for Tally inputs (GND)