Table of Contents

Advertisement

MAGNER 910 Operation Manual V1.1
VALUE: refers to the denomination
COUNT: refers to the quantity for each denomination
AMOUNT: refers the amount for each denomination
Data Clear:
·Under main modes interface, press CLR key to clear all counted data.
·Under main modes interface, press ESC key to clear rejected coin
record.
Data Memory:
.Under main interface, press M+ Key to save the quantity and amount
for genuine coins. It saves the accumulated data of the counting
results. Under main interface, when the counting quantity and
amount for genuine coins is 0, you can press M+ key to clear the
saved data .
. Under self-learning interface, press M+ Key to save the self-learning
data, this function is only available for maintenance people
Data Memory Read:
·Under main modes interface, press MR key to read stored data;
·Under self-learning interface, press M+ Key to read the original
self-learning data, this function is only available for maintenance
people

8. Function Settings

Press SET key to enter into Menu interface, shown as follows:
> 1.BATCH
2.VALUE
3.SYSTEM
Directly press
and then press SET key to enter each into detailed operation
MENU
4.TOTAL
5.TEST
6.LEARN
four keys to choose target submenu
Page 9 of 18