  • Page 1 COIN SORTER MAGNER 910 Operation Manual...
  • Page 2: Table Of Contents

    MAGNER 910 Operation Manual V1.1 CONTENTS 1. Introduction ............3 2. Specifications ............. 3 3. Diagram ............. 4 4.Socket board ............5 5. Key Panel ............6 6. Main Display Modes ..........7 7. Operating Procedures ......... 7 8. Function Settings ..........9 9.
  • Page 3: Introduction

    MAGNER 910 can automatically recognize foreign coins, counterfeit coins and sheet metals etc. MAGNER 910 can sort 9 kinds of coins at the same time and has the function of automatically detecting,...
  • Page 4: Diagram

    MAGNER 910 Operation Manual V1.1 3. Diagram ①:Key panel ②:Presorting tray ③:Visible window ④:Handle ⑤:Socket board ⑥:Printer ⑦:Drawer Page 4 of 18...
  • Page 5: Socket Board

    MAGNER 910 Operation Manual V1.1 4.Socket board ⑧:Power socket ⑨:Power switch ⑩:LAN(reserved socket for network) ⑪ :USB(for software upgrading) ⑫ :PS2(reserved socket for external display) ⑬ :RS232(communication with PC) Page 5 of 18...
  • Page 6: Key Panel

    MAGNER 910 Operation Manual V1.1 5. Key Panel Key Function: 1) 0 ~ 9 : Numeric key for fast batch number settings 2) START /STOP: Start or Stop 3) SET: Set MENU or set some functions 4) ESC: Return to MENU or clear rejected coin records 5)...
  • Page 7: Main Display Modes

    MAGNER 910 Operation Manual V1.1 Main Display Modes 1)Total Amount & Quantity Display Mode: MIX- COUNT STOP VALUE: 125.90 COUNT: 2)Separate Channel Amount & Quantity Display Mode: AMOUNT VALUE COUNT 100.00 2.00 25.00 0.50 0.90 0.01 7. Operating Procedures Turn on the machine, the machine will enter into self-test mode and...
  • Page 8 MAGNER 910 Operation Manual V1.1 MIX- COUNT STOP VALUE: 0.00 COUNT: MIX-COUNT means mix-counting mode RUN/STOP is the sign showing machine’s running or stop status. B is the sign of Batch Function is ON. VALUE is for total Amount. COUNT is for total Quantity, F shows the quantity of foreign/fake coins.
  • Page 9: Function Settings

    MAGNER 910 Operation Manual V1.1 VALUE: refers to the denomination COUNT: refers to the quantity for each denomination AMOUNT: refers the amount for each denomination Data Clear: ·Under main modes interface, press CLR key to clear all counted data. ·Under main modes interface, press ESC key to clear rejected coin record.
  • Page 10 MAGNER 910 Operation Manual V1.1 interface: (1) BATCH BATCH SET 2.00 CHANNEL: VALUE: BATCH: 0000 Enter into BATCH SET interface,press key to switch the , channel. Under one channel, press SET key, the BATCH will flash, at this moment you can set the BATCH value through the numeric key ~ 9 (the upper limit is 9999)...
  • Page 11 MAGNER 910 Operation Manual V1.1 OK” and flash. At this moment, you need to clear the drawer for 2.00 and press CLR to clear the message, otherwise other key functions are not workable. (2) VALUE VALUE SET CHANNEL: VALUE: 2.00 Under VALUE interface,press...
  • Page 12 MAGNER 910 Operation Manual V1.1 >DATE:2013-08-29 TIME: 05:44:32 Under this interface, if you need to update date and time, please firstly press SET key to make the cursor blinking and then by press key to make the cursor moving. Directly press 0~9 numeric key to set your desired date and time.
  • Page 13 MAGNER 910 Operation Manual V1.1 Under this interface, please press key to choose PRINT 0 or set BAUD rate. Press SET key to choose either one, and then press key to turn ON/OFF the function. After setting, press ESC key to return to main menu interface.
  • Page 14: Trouble Shooting

    MAGNER 910 Operation Manual V1.1 (6) LEARN This submenu is for coin self-learning parameter tests and adjustments. It is not available for users. 9. Trouble Shooting During self-testing or machine working status, sometimes the LCD screen may display following error code: (1)ERROR ADJUST...
  • Page 15 MAGNER 910 Operation Manual V1.1 covers the 2 solenoid triggering sensor. Please check and clean this part, including all connecting wires check. After solving this problem, press CLR key to come back into main display modes interface. (4)ERROR 03 ERROR: CHECK THE SENSOR 3 ·When it displays such error message, it means there is foreign thing...
  • Page 16 MAGNER 910 Operation Manual V1.1 problem, press CLR key to come back into main display modes interface. (7)ERROR 06 ERROR 05 TRAY : 2 FULL PLEASE EMPTY THE TRAY ·When it displays ERROR 06, it means the Optical tube assembly for second solenoid is counting abnormally.
  • Page 17: Precautions

    MAGNER 910 Operation Manual V1.1 WARNING BOX:2 FULL PLEASE CLEAR THE BOX ·When it displays such WARNING message, it means the genuine coin drawer or rejected coin drawer is full, please take out all coins. After this, press CLR key to come back into main display mode interface.
  • Page 18: Accessories

    MAGNER 910 Operation Manual V1.1 12. Accessories 1. Power Cable 2. Nylon Brush 3. Coin Scoop 4. Turn brush *** In the interests of our ongoing policy of continual product improvement, specifications are subject to change without prior notice. Page 18 of 18...