Summary of Contents for Longray TS35N

  • Page 1 Longray User Manual calibration ignition screw gas valve on/off pump solution tap drain solution tank fuel tank TS35N, TS35NE c 2018 Longray. All rights reserved.
  • Page 2: Table Of Contents

    Contents 1 Warnings 2 Warnings for indoor operation 3 Tech specs Flow rates ....... . 4 Install Installing the cooling tube .
  • Page 3: Warnings

    Warnings Do not use the machine to spray humans or animals. After spraying, use water to clean the solution tank and pipeline. This is especially important for corrosive chemicals. Strongly corrosive chemicals (such as peroxyacetic acid) may damage the unit. Limit to occasional use, and spray 1/4 gallon of clean water afterwards.
  • Page 4: Warnings For Indoor Operation

    Warnings for indoor operation In closed spaces, operator should wear a breathing mask. Do not leave a running fogger unattended. Some aerosol carriers become flammable at high concentrations. Do not exceed these limits per 1000 m . Special carriers Nebal 3.0L Glyzerine 2.5L...
  • Page 5: Tech Specs

    Tech specs Exact specifications depend on altitude and temperature. Solution flow rate 5.2 gal/hr Solution capacity 1.6 gal Solution pressure 0.2 bar Fuel engine 25.2 hp Fuel consumption 0.4-0.5 gal/hr Fuel capacity 0.4 gal Fuel pressure 0.1 bar Fuel type regular gasoline Batteries 4 x D batteries...
  • Page 6: Install

    Install Installing the cooling tube 1. Using the included wrench, remove nozzle screw and nozzle connector. Detach solution pipe. 2. Pull out the inner cage...
  • Page 7 3. Slide in the cooling tube. For oil-based solutions, the end with 4 holes should face outward. For water-based solutions, the end with 1 hole should face outward 4. Align the opening in cooling tube with the opening in the inner fogging pipe.
  • Page 8 6. Reinstall the solution pipe. Use one wrench to hold the nozzle connector in place while using the second wrench to tighten the nozzle screw. If not tight, solution may leak.
  • Page 9: Operation

    Operation Prep 1. You must install the cooling tube before operating the fogger. Follow the instructions in the install section. 2. Install 4 x “D” batteries into the battery compartment at the base of the nozzle. 3. Fill gas tank to between 1/4 and 3/4 full. 4.
  • Page 10: To Start Spraying

    To start spraying 1. Open the gas valve by pulling up. 2. With your right hand on the ignition button, use your left hand to make full-length pumps, one cycle per second. 3. Pump faster as you hear engine start, until it runs continu- ously.
  • Page 11: To Stop Spraying

    To stop spraying 1. Turn solution tap to CLEAN. This releases the solution pres- sure. 2. Once the spray dies down, turn solution tap to OFF. You must turn off solution tap before shutting off the en- gine in the next step, otherwise solution left in the fogging tube will burn.
  • Page 12: Troubleshooting

    Troubleshooting Engine does not start WARNING: Do not try to take apart the engine. Doing so can damage it. Follow the Reset Procedure in the Appendix, and try again. If the ma- chine still doesn’t start: 1. Check ignition box by pressing the ignition button. should here a “Ta Ta Ta”...
  • Page 13: Engine Starts, But No Fog Comes Out

    Engine starts, but no fog comes out 1. Make sure solution tap is turned to ON. 2. Open the solution tank lid, and check the rubber gasket inside the lid is in place. 3. Check solution tank pressurization. Start up the machine, remove the solution tank lid, and cup your palm over the solution tank opening.
  • Page 14: Nozzle Emits Flame

    4. If you cannot feel solution pressure, check the airway tube for damage. The airway tube is the top tube in this picture. 5. Check the solution filter for clogging. 6. Clean the solution pipeline - see appendix. 7. Check the solution tap for jamming. 8.
  • Page 15: Appendix

    Appendix Reset procedure 1. If the solution tap is ON, turn it OFF. 2. Close the gas valve by pushing down. 3. With right hand on ignition button, use left hand to push and pull the air pump. 4. Pump until there are no more engine pops, or after 8-10 pumps. Engine power setting Your machine’s engine power was set at the factory.
  • Page 16: Cleaning The Diaphragm

    Cleaning the diaphragm If the diaphragm in the air intake is wet, dislocated, or damaged, the engine may suffer airflow issues and not start. Follow these steps to remove the diaphragm for cleaning.
  • Page 17 Use a soft cloth to wipe the diaghragm. Make sure the diaphragm is dry, wrinkle-free, and sits flat and centered. Follow the instructions in reverse to reinstall. Be sure to tighten the central nut in step 6.
  • Page 18: Cleaning The Solution Pipeline

    Cleaning the solution pipeline 1. Use wrenches included in the spare parts kit to take apart the solution pipeline. 2. Use a thin wire to clean out the nozzle. 3. Scrape away any residue in the connecting joint.
  • Page 19 4. Remove any deposited carbon from the pipeline connector.
  • Page 20: Automatic Cutoff Device

    Automatic Cutoff Device In the usual shutdown procedure, solution flow is turned off before the engine is turned off, since solution that is allowed to settle in the still-hot fogger tube can burn. If the engine shuts off unexpectedly, for example if gas runs out, then you may not have time to turn off...