12. MAINTENANCE INSTRUCTIONS
12.1.
Before performing maintenance, unplug and disconnect the battery charger (see sections 5.8 and 6.7).
12.2.
After use, unplug the charger and use a dry cloth to wipe all battery corrosion and other dirt or oil from the terminals, cords, and the
charger case.
12.3.
After every 100 hours or whenever you see dust accumulating on the fan blades, you should clean both fans using compressed air
(as shown).
NOTE:
Use the compressed air on the fan blades only. Do not blow dirt into the fan shaft or bearing. These fans push
a lot of air and are precision balanced. Excessive dirt and grime build up will cause the fan to be unbalanced
and wear out quickly. If the fans fail, the charger may overheat and the thermal protection of the charger will
shut it down.
12.4.
Ensure that all of the charger components are in place and in good working condition, including the plastic
boots on the battery clips.
12.5.
Servicing does not require opening the unit, as there are no user-serviceable parts.
13. MOVING AND STORAGE INSTRUCTIONS
13.1.
If the charger is moved around the shop or transported to another location, take care to avoid/prevent damage to the cords, clips and
charger. Failure to do so could result in personal injury or property damage. DO NOT store the clips on the handle, clipped together, on
or around metal, or clipped to cables.
13.2.
Store the charger unplugged. The cord will still conduct electricity until it is unplugged from the outlet.
14. SPECIFICATIONS
Input..............................................................................................220-240V~ 50/60Hz 10A
Output:
Charging mode..................................................................................12V
Desulfation mode...............................................................................................15.8V max.
Reprogram mode.............................................13-14.8V
Weight......................................................................................................................9.56kg
Operating temperature.....................................................-20 °C – +40 °C (-4 °F–+104 °F)
Operating humidity.................................................................0 – 90% RH non-condensing
Working life (MTBF)........................................................................................85,000 hours
© Jack Sealey Limited
4A / 20A / 70A
0-70A, 100A for three minutes
Original Language Version