Specifications

5

Electrical

5.1
Max Continuous Force (N) Fluid/Air
Max Continuous Current (Arms) Fluid/Air
1,2
Peak Force over 1 second (N)
Peak Current over 1 second (Arms)
Peak Force over 16 seconds (N)
Peak Current over 16 seconds (Arms)
Force Constant [K
] (N/Arms)
f
Back EMF Constant [K
] (V
e
5
Resistance @ 25°C (Ω)
5
Inductance (mH)
Maximum Motor Voltage (V
Electrical Time Constant (ms)
Magnetic Pitch (N-N) (mm)
NOTES:
1.
The maximum continuous force and current when the forcer is stationary (worst-case) is given for both
fluid cooling (first figure) and air-natural cooling (second figure). Air-cooled ratings are based on an
ambient temperature of 25°C and fluid cooled ratings based on a coolant temperature 25°C (flow rates
in
Table
5-2). The quoted air-cooled ratings assume a standard mounting configuration (see
where the motor is attached to a steel carriage via two metal brackets.
2.
The maximum continuous ratings for both Fluid and Air cooling are based on a winding temperature of
130°C absolute maximum. This is "Class B" operation. The windings however, are manufactured with
"Class H" materials, and therefore have a safety margin of two full classes.
3.
The maximum peak force and current is a limitation due to permanent magnet characteristics and
should never be exceeded even for a short time.
4.
If the linear motor is used repetitively at peak forces in excess of the nominal, the equivalent rms loading
shall be taken into account, along with forces that are below the nominal figure. The application duty
cycle should be calculated over a period of 10 minutes. Further, sufficient Voltage must be available
from the Servo Drive to overcome both the resistance, and the back-emf of the linear motor (depending
on the speed). Refer to
The Resistance and Inductance values are "between phases" or "line to line" and are twice the per-
5.
phase parameters. The resistance is taken at 25°C. Resistance values will increase by 40% at the
design operating temperature of 130°C. Inductance measurement is performed at 1kHz.
6.
The linear motor winding insulation is designed for PWM operation at a maximum motor voltage of 420V
rms line-line from a maximum DC Bus Voltage of 680V DC.
ANCA Motion
TLMS-18P
1,2
335 / 207
3.85 / 2.38
3,4
2136
3,4
24.6
4
522
4
6
87
/(m/s))
50
rms L-L
10.4
29
6
)
420
rms L-L
2.8
180
Table 5-1 - Electrical Specifications
5.2 Force vs. Speed
Characteristics.
D-000168 Rev 02
TLMS-27P
TLMS-36P
510 / 290
630 / 360
5.86 / 3.33
7.24 / 4.14
3204
4272
36.8
49.1
783
1044
9
12
87
87
50
50
6.9
5.2
19.3
14.5
420
420
2.8
2.8
180
180
5
Specifications
TLMS-36H
630 / 360
3.62 / 2.07
2860
16.4
1044
6
174
100
20.8
58
420
2.8
180
Figure
3-2)
19