Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
PRODUCT OVERVIEW Chapter 1 – Product Overview Overview ® ® The MultiConnect Dragonfly Nano (MTQN) embedded cellular modem is a small version of the MultiConnect Dragonfly (MTQ) embedded cellular modem. Both devices offer developers the functionality of an on-board cellular radio all-in-one compact design. The Dragonfly Nano provides a practical solution to the market's demand for a smaller, low-power modem.
HARDWARE AND SPECIFICATIONS Category Description Radio Compliance FCC Part 22, 24, 27 Safety Compliance UL/cUL 60950-1 2nd ED, IEC 60950-1 2nd ED +Am.2 Network PTCRB Carrier AT&T Verizon 40-Pin Connector Definitions The Dragonfly™ Nano offers developers an FCC and carrier certified solution that makes connecting sensors and other edge-of-network devices quick and easy.
HARDWARE AND SPECIFICATIONS Pin Definitions Signal Name I/O Level In/Out Description Power Ground Connection USB-DATA+ USB Data+ connection to cellular module USB-DATA- USB Data- connection to cellular module VCC-IN Power Power Input RADIO_RX Cellular Radio UART Data Output RADIO_DCD Cellular Radio UART DCD Output RADIO_RI Cellular Radio UART RI Output RADIO_CTS...
HARDWARE AND SPECIFICATIONS Signal Name I/O Level In/Out Description RADIO_DSR Cellular Radio UART DSR Output RADIO_DTR Cellular Radio UART DTR Input RADIO_TX Cellular Radio UART Data Input VCC-IN Power Power Input LINK 3.3 - 4.2 (see note) Radio Link Status NRESET 3.3 - 4.2 (see note) Board Reset Input...
HARDWARE AND SPECIFICATIONS Electrical Characteristics Operating Conditions Parameter Minimum Volts Maximum Volts Supply Range - Vcc 5.25 Absolute Maximum Rating Symbol Description Conditions Min. Max. Unit Module supply voltage Input DC voltage at VCC pin -0.5 Generic digital interfaces Input DC voltage at Generic -0.5 digital interfaces pins SIM interface...
HARDWARE AND SPECIFICATIONS Power Draw Voltage Radio Power Saving (AVG) Measured TX Pulse (AVG) Total Inrush Protocol Mode and Current at Max Amplitude Current for Charge Power Down Power Peak Current MilliCoulombs (mC) 5 Volts with 15 μA 172 mA 381 mA 0.04 mC Unit In Dev Card...
ANTENNAS Chapter 4 – Antennas Antenna Devices were approved with the following antenna or for alternate antennas meeting the given specifications: Manufacturer: Wieson Description: LTE Antenna with SMA-Male Connector Model Number GY115IE002-001 MultiTech ordering information: Model Quantity ANLTE4-1HRA ANLTE4-2HRA ANLTE4-10HRA ANLTE4-50HRA Antenna Specifications Category...
SAFETY INFORMATION Chapter 5 – Safety Information Handling Precautions To avoid damage due to the accumulation of static charge, use proper precautions when handling any cellular device. Although input protection circuitry has been incorporated into the devices to minimize the effect of static build-up, use proper precautions to avoid exposure to electronic discharge during handling and mounting the device.
SAFETY INFORMATION General Safety The device is designed for and intended to be used in fixed and mobile applications. Fixed means the device is physically secured at one location and cannot be easily moved to another location. Mobile means the device is used in other than fixed locations.
SAFETY INFORMATION UL evaluated this device for use in ordinary locations only. UL did NOT evaluate this device for installation in a vehicle or other outdoor locations. UL Certification does not apply or extend to use in vehicles or outdoor applications.
GETTING STARTED Chapter 6 – Getting Started Communicating with the Device Following are three options for communicating with the device. Install USB drivers and plug into the micro USB connector. No need for a host board. Access the device's USB interface via pins 6, 7, and 24 of the 40-pin connector. Data pins 6 and 7 are parallel with the micro USB connector on the MTQN.
Page 18
GETTING STARTED The MNG1 model is licensed to operate on both Verizon or AT&T networks. Refer to the Sara-R4/N4 series AT Commands Manual for more details. Note: If your device is on +UMNOPROF: 0 (SW default), there is no network and you must set one. Set at the factory (factory default on MNG1): This command sets your device in Cat M1 mode: AT+URAT=7...
GETTING STARTED To configure the supported radio bands: Use the +UBANDMASK command if your MNO is not listed by the +UMNOPROF command. Refer to your specific carrier regarding available bands. USB Driver Installation For the Windows USB driver, refer to the SARA-R4 USB Driver Installation Guide on the product page of the Multitech website.
AT COMMANDS Chapter 7 – AT Commands Powering Down the Device CAUTION: Failing to properly power down the device before removing power may corrupt your device's file system. Following are two options that power down the device while maintaining the current parameter settings and allowing for a clean network detach.
LABELS Chapter 8 – Labels Approvals and Certifications This device is an industry and/or carrier approved modem. In most cases, when integrated and used with an antenna system that was part of the MultiTech modem certification, additional approvals or certifications are not required for the device that you develop as long as the following requirements are met: PTCRB Requirements: The antenna system cannot be altered.
REGULATORY INFORMATION Chapter 9 – Regulatory Information 47 CFR Part 15 Regulation Class B Devices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Page 23
REGULATORY INFORMATION UMTS CH 2 UP UMTS CH 25 UP UMTS CH 35 DOWN The following table provides the certified radio frequency data for this device: FCC Rule Frequency Range Output Watts (mW) Frequency Tolerance Emission Parts Designator 699 - 716 MHz 0.316 1.0 PM 1M11G7D...
Certificate of Compliance 2011/65/EU Multi-Tech Systems, Inc. confirms that its embedded products comply with the chemical concentration limitations set forth in the directive 2011/65/EU of the European Parliament (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment - RoHS).
After careful review of the legislation and specifically the definition of an “article” as defined in EC Regulation 1907/2006, Title II, Chapter 1, Article 7.1(a)(b), it is our current view that Multi-Tech Systems, Inc. products would be considered as “articles.” In light of the definition in § 7.1(b) which requires registration of an article only if it contains a regulated substance that “is intended to be released under normal or reasonably foreseeable conditions...
Products (EIP) # 39, also known as China RoHS, the following information is provided regarding the names and concentration levels of Toxic Substances (TS) or Hazardous Substances (HS) which may be contained in Multi-Tech Systems Inc. products relative to the EIP standards set by China's Ministry of Information Industry (MII).
INDEX Index absolute maximum rating ..........11 labels ................21 antenna .................13 operating conditions .............11 build options ..............5 Chinese hazardous substances connector definitions..........8 Chinese version............26 power down device............20 English version ............27 power draw MTQN-MNG1-B02............12 documentation..............5 drawings................6 RoHS................24 electrical characteristics..........11 specifications..............7 hazardous substances ...........24 usb cable ...............12 install SIM card..............17 ®...
Need help?
Do you have a question about the MultiConnect Dragonfly Nano MTQN-MNG1-B02 and is the answer not in the manual?
Questions and answers