1. Subject to clauses 2 & 3 of this warranty, A.F. Gason Pty Ltd ACN 004 667 556 warrants the following components of its heaters against defects in workmanship
and/or materials for the following periods from the date of purchase:
a) the rebox for ten years;
b) the paint nish for a period of 12 months if the purchaser has followed the instructions provided by Gason in the operation and Installation Instructions manual; and
c) all other components for 12 months except the glass, re brick lining or ba e plate if, in the opinion of Gason, these items have been damaged by impact.
2. This extended warranty does not apply;
a) if the heater is purchased from a person who has not been authorised by Gason to sell its products;
b) if, in the opinion of Gason, the heater or any other component has been subject to abuse, misuse, alteration, modi cation or has not been installed, operated or maintained in
accordance with the instructions provided by Gason; or,
c) to owners other than the original purchaser.
3. If you believe that the heater you purchased contains a manufacturing defect and you wish to make a claim under this warranty, please contact an authorised Gason service
centre to arrange for an assessment.
4. If, after assessing the heater, Gason determines that the heater contains a manufacturing fault, Gason may at its discretion:
a) replace the heater;
b) repair or replace speci c components of the heater; or
c) provide a full refund.
5. Parts replaced under warranty are warranted for the balance of their original warranty period.
6. If, at the discretion of Gason, the heater or any part needs to be replaced, serviced or repaired at an authorised Gason service centre, then the person claiming under this
warranty must pay all costs associated with:
a) returning the heater; and
b) the delivery or collection of any new or repaired heater.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality
and the failure does not amount to a major failure.
Any bene ts you receive under these warranties are in addition to other rights and remedies that you may have as a consumer under law in relation to the heater to which
these warranties relate.
These warranties are given by:
AF Gason Pty Ltd
Blake Street
Ararat VIC 3377
Please contact us if you have any queries on:
Phone: 03 53522151
or email us via the "Contact Us" section of our website: www.gason.com.au
751
680
650
596
290
325
855
836
763
850

WARRANTY

16
680
Operation & Installation Instructions
Rev B
Tilga Insert
Masonry & Zero Clearance Installation
Please keep these instructions for future reference.
*Compliance Plate is located on the rear of the appliance fascia.
232346

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tilga and is the answer not in the manual?

Questions and answers

Summary of Contents for Jindara Tilga

  • Page 1 Tilga Insert Jindara Tilga for masonry installation Package dimensions: 1075Wx660Dx800H Jindara Tilga for ZCC installation Package dimensions: 915Wx695Dx1025H WARRANTY 1. Subject to clauses 2 & 3 of this warranty, A.F. Gason Pty Ltd ACN 004 667 556 warrants the following components of its heaters against defects in workmanship and/or materials for the following periods from the date of purchase: a) the rebox for ten years;...
  • Page 2 A wood’s e ciency does not depend only on its type, but also on its moisture content as well as the temperature of the appliance. combustion chamber. To achieve a greater e ciency and longer burn cycle out of your Jindara Tilga, without the emissions •...
  • Page 3: Troubleshooting

    Squeeze locator tabs together on the rear of the thermostat switch and push through outside of pedestal. Disconnect the wiring from the power lead and remove the fan. Convey the same to the authorised Jindara Dealer from AF Gason Pty. Ltd. accepts no liability whatsoever for any interpretation of AS/NZS 2918:2001.
  • Page 4 Clearance to combustibles & Zero Clearance Cabinet (ZCC) installation Below, Figure 2 shows an example of how the Eureka Tilga Insert with ZCC should be placed in relation to combustible materials - plaster, wallpaper, timber, MDF etc. These clearances from the ZCC to combustible materials must not be reduced.
  • Page 5 Hearth & oor requirement If the Jindara Tilga will be installed directly onto a non-combustible oor such as brick, stone or concrete slab with tiles, etc. which extends beneath the appliance as well as 550mm in front of the appliance fascia when in position, a hearth or oor protector may not be required.
  • Page 6 Each time you do this you will notice that the brush will go further down the chimney until it reaches the bottom. • Select the position that you wish to install your Jindara Tilga Insert ZCC, carefully allowing for flue clearances of 305mm in the The soot and creosote will fall down the chimney and into the rebox.
  • Page 7 Fan operation Ba e System Your Jindara Tilga is equipped with a temperature-sensitive thermostat switch located within the heater’s fascia beneath the rebox, which when selected will turn the fan on and o depending on the temperature of the rebox.
  • Page 8 Tilga Insert Tilga Insert Installation Operating your Jindara (Continued) Flue and chimney requirements The ue pipe shall extend not less than 4.6m above the top of the oor protector. Note: Installation must be DO NOT ATTEMPT TO OPERATE THIS APPLIANCE WITHOUT READING AND WARNING carried out by a licensed installer in accordance with AS/NZS 2918:2001.

Table of Contents