Dimplex DXLWP400TS Installation And Operating Instructions Manual page 6

Low wattage panel heater
Table of Contents

Advertisement

Auto/Timer mode - Week Program
NOTE
For extended operation, it is advisable to use the AUTO/
TIMER operating mode to reduce the operating costs.
Four times blocks are available per day. These can
be adapted individually for each weekday.
• Select AUTO operating mode by pressing the
MODE button.
• Press the PROG key. WEEKDAY display flashes.
Order from top to bottom:
M = Monday,
T = Tuesday,
W = Wednesday,
T = Thursday,
• Use the +/- keys to set the weekday.
Setting time block ON
• Press the ENTER key. P1 (program 1) and ON
appears, The hours display flashes.
• Use the +/- keys to set the hours. Press the
ENTER key. The minutes display flashes.
• Use +/- to set minutes (in 10 minute increments).
Setting time block OFF
• Press the ENTER key. P1 (program 1) and OFF
appears, The hours display flashes.
• Use the +/- keys to set the hours. Press the
ENTER key, The minutes display flashes.
• Use the +/- keys to set the minutes.
Temperature setting
• Press the ENTER key. Temperature setting appears.
• Use the +/- keys to set the temperature.
•Press
the
ENTER
and ON appears, The hours display flashes. The
programs P2, P3 and P4 can be set in the same way.
NOTE
To exit the program early, press the PROG key
F = Friday,
S = Saturday,
S = Sunday.
M
T
W
T
F
S
S
key.
P2
(program
Copying programs
To copy the newly set programs P1 - P4 to other
days, proceed as follows.
• After carrying out the Temperature Setting, press
and hold the ENTER key until COPY appears.
• Press + to select more weekdays. The selected
weekdays are marked with a triangle displayed
permanently. The days Monday to Friday are
selected on the screen at the top
• Deselect weekdays with the - key. Press the
ENTER key. The settings are saved. COPY flashes
three times. Setting is complete.
Frost protection
In MANUAL OFF operating mode and Auto
operating mode (time block OFF), frost protection
takes place. If the room temperature is 5° C or less,
the heating device is switched on automatically.
Adaptive start up
While the product is in timer mode, this function
prewarms the room so it is not as cold at the start of
the switch on time.
Example:
In the timer menu, a set room temperature of 22°C
is specified. The current room temperature is 17° C.
The heating device switches on early so that the
specified room temperature of 22° C is reached by
07:00.
2)
• Use the MODE key to select the operating mode
AUTO (Timer).
• Press and hold the + key and the - key for three
seconds.
• ECO appears.
M
T
W
T
F
S
S
ON

Advertisement