Advertisement

Quick Links

PVMET-330
User's Guide
03/27/18
Rev. 2

Advertisement

Table of Contents
loading

Summary of Contents for RainWise PVMET-330

  • Page 1 PVMET-330 User’s Guide 03/27/18 Rev. 2...
  • Page 2 Copyright © 2018 by RainWise, Inc. All rights reserved. No part of this work may be reproduced in any form except by written permission of the publisher. All rights of translation are reserved. PVMET-330™ is a trademark of RainWise, Inc. - 2 -...
  • Page 3: Table Of Contents

    INTRODUCTION......................4 INSTALLING THE WEATHER STATION ..............4 ..............4 EQUIREMENTS AND ONSIDERATIONS ......................... 5 NSTALLATION Weather Station ......................5 Anemometer ........................ 5 ..........................5 IRING Connecting RS-485 ..................... 5 Connecting the Power Supply ..................6 MODBUS RTU ....................... 6 ......................
  • Page 4: Introduction

    It measures ambient air temperature, relative humidity, barometric pressure, wind speed and direction and is capable of measuring rainfall, soil or other peripheral temperature and global irradiance. The PVmet-330 uses a 2-wire half duplex RS-485 serial port for Modbus RTU communication with a host.
  • Page 5: Installation

    By default the PVmet-330 is configured for operation in the Northern hemisphere. This only requires that the irradiance sensor faces due South. If the PVmet-330 is going to be used in the Southern hemisphere it must be mounted with the irradiance sensor facing North.
  • Page 6: Connecting The Power Supply

    Signal/Power Ground +VDC: External 10-30VDC Supply RS-485 is rated to 4,000 feet (1,200 m) at 90 kbps. The RS-485 port on the PVMET-330 is surge protected but not isolated. Connecting the Power Supply The weather station can either be powered from its own battery and solar panel or from an external power source (depending on model).
  • Page 7: Unsupported Fields

    The register map reserves registers for all combinations of sensors supported by the Rainwise stations. Not all will be available on any one system. Sensors/fields that are not supported will contain the value 0x8000. Some fields require the purchase of additional sensors.
  • Page 8: Modbus Map

    MODBUS MAP Holding Scale Register Item Type Units Factor Contents Manufacturer uint16 "RW" (0x5257) "S0"=MK-III, "S1"=AgroMet, "S2"= Model uint16 PVmet 0x0170, "01" Map Version, Version uint16 "70" Firmware Version Degrees Air Temperature int16 Measured Humidity int16 Measured Pressure int16 Measured Wind Speed int16 Measured...
  • Page 9: Changing The Modbus Device Address

    Changing the Modbus Device Address The Modbus device can be changed using the dipswitches 1 & 2 with the default position set to device address 60. Modbus Address Switch 1 Switch 2 Changing the Baud Rate The baud rate can be set to either 9600 or 19200. The default baud rate is 9600. Changing dipswitch 5 to the ON position will change the baud rate to 19200.
  • Page 10: Minimum System Requirements

    9600/19,200 bps Parity: None Data bits: Stop bits: Flow Control: None Interface mode: 2-Wire Half Duplex Software The PVMET-330 is designed to work with an RS-485 compliant host. A terminal emulator program is required to change settings. - 10 -...
  • Page 11: Sensor Assembly

    Material Specifications Sensor Assembly: RoHS Compliant Mast: Polyvinyl Chloride Heat Shields: Acrylonitrile Butadiene Styrene Insolation Sensor Bracket: Delrin Hardware: Stainless Steel and Nylon Locknut Foam Gasket: Vinyl and Acrylic Enclosure: RoHS Compliant IP65 Rated Outdoor Enclosures UL 94 V-2 Body: Polycarbonate Pyranometer Sensor: RoHS Compliant...
  • Page 12: Hardware Specifications

    Greater of 0.45m/s (1 mph) or 5% of Reading Resolution: 0.045 m/s (0.1 mph) Threshold: 0.65 m/s (1.45 mph) RainWise Liquid Precipitation: Operational Temperature: 0 ~ 85°C (0 ~ 185°F) Range: 0 ~ 762 mm/hr (0 ~ 30 in/hr) Accuracy: ±2% at 25.4 mm/hr (±2% at 1 in/hr)
  • Page 13: Apogee Pyranometer Sensor

    0 ~ 1750 W/m Accuracy: ±5% Cosine Response 45°: ±1% Cosine Response 75°: ±5% Resolution: 1 W/m RainWise B.O.M Temperature: Range: -55 ~ 85°C (-67 ~ 185°F) Accuracy: ±0.2°C at 25°C (±0.4°F at 77°F) Resolution: 0.056°C (0.1°F) - 13 -...
  • Page 14: Contact Information

    RainWise, Inc. will not reimburse for take-down or installation charges. RainWise, Inc. will not pay for warranty service performed by a non-authorized repair service and will not reimburse the consumer for damage resulting from warranty service performed by a non-authorized repair service.