Lateral installation
Rod extension
PBD-51041064
ø < 8 mm
(ø < 0.315")
Fig. 13: Tensioning component for cable versions
1
Holding screw M8
2
Holding screw M12
L1 Max. measuring length
Probe length L = L1 + 270 mm (10.63 in)
In case of difficult installation conditions, the probe can also be
mounted laterally. For this, adapt the rod with rod extensions or
angled segments.
To compensate for the resulting changes in signal runtime, let the
instrument determine the probe length automatically.
The determined probe length can deviate from the actual probe
length when using curved or angled segments.
If internal installations such as struts, ladders, etc. are present on the
vessel wall, the measuring probe should be mounted at least 300 mm
(11.81 in) away from the vessel wall.
You can find further information in the supplementary instructions of
the rod extension.
In case of difficult installation conditions, for example in a socket, the
probe can be suitably adapted with a rod extension.
To compensate for the resulting changes in signal runtime, let the
instrument determine the probe length automatically.
You can find further information in the supplementary instructions of
the rod and cable components.
SITRANS LG270 - Operating Instructions
1
M8
M12
2
550 mm
(21.65")
23