IMEON ENERGY IMEON 9.12 Installation Manual page 88

Hide thumbs Also See for IMEON 9.12:
Table of Contents

Advertisement

Available languages

Available languages

Code
Type
94
error_ond
95
error_ond
96
error_ond
97
com_lost
98
error_spe
FR
99
error_spe
FR
EN
100
error_spe
ES
101
error_spe
102
error_spe
103
error_spe
104
error_spe
105
error_spe
106
error_spe
107
error_spe
108
error_spe
109
error_spe
110
error_spe
111
error_spe
112
error_ond
88
Manuel d'installation / Installation guide IMEON Inverter/ Guia de montaje – Rev C.12
IMEON INVERTER
PV2 input power overpasses specification. This problem can cause a critical electronic
damage. Please check the PV sizing, connection and installation. If the problem remains
contact your distributor.
Temperature exceeds the specification of the inverter. Please check the installation, this
problem can cause a critical electronic damage. If the problem remains contact your
distributor.
Battery discharging current overpasses specification of the inverter. Please check the
installation, this problem can cause a critical electronic damage. If the problem remains
contact your distributor.
Communication lost between Inverter and Smartmeter. Please check the wiring between
Smartmeter and inverter. If the problem remains, contact your distributor.
Voltage on grid connection exceeds minimum voltage specification. Please check the
installation, this problem can cause a critical electronic damage. If the problem remains
contact your distributor.
Voltage on grid connection exceeds maximum voltage specification. Please check the
installation, this problem can cause a critical electronic damage. If the problem remains
contact your distributor.
Frequency on grid connection exceeds minimum frequency specification. Please check the
installation, this problem can cause a critical electronic damage. If the problem remains
contact your distributor.
Frequency on grid connection exceeds maximum frequency specification. Please check the
installation, this problem can cause a critical electronic damage. If the problem remains
contact your distributor.
Voltage on AC BACKUP exceeds minimum voltage specification.
Please check the installation, this problem can cause a critical electronic damage. If the
problem remains contact your distributor.
Voltage on AC BACKUP exceeds maximum voltage specification.
Please check the installation, this problem can cause a critical electronic damage. If the
problem remains contact your distributor.
Power on AC BACKUP overpasses maximum power specification. Remove the high power
devices with inrush power. This problem can cause a critical electronic damage. If the
problem remains contact your distributor.
Voltage on DC bus overpasses maximum voltage specification. Please check the
installation, this problem can cause a critical electronic damage. If the problem remains
contact your distributor.
Voltage on Battery overpasses maximum voltage specification. Disconnect the battery and
check the voltage on terminal complies with inverter specifications. If the problem remains
contact your distributor.
PV input current overpasses specification. Stop the PV production and check the PV sizing,
connection and installation. If the problem remains contact your distributor.
PV2 input current overpasses specification. Stop the PV production and check the PV sizing,
connection and installation. If the problem remains contact your distributor.
PV input voltage overpasses specification. Stop the PV production and check the PV sizing,
connection and installation. If the problem remains contact your distributor.
PV2 input voltage overpasses specification. Stop the PV production and check the PV
sizing, connection and installation. If the problem remains contact your distributor.
Battery charging current overpasses specification of the inverter. Please check the
installation, this problem can cause a critical electronic damage. If the problem remains
contact your distributor.
Neutral / Ground wires reversed. Stop the inverter and check the Neutral and Ground wires
are not reversed on "GRID CONNECTION" connector and "AC BACKUP" connector. If the
problem remains contact your distributor
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imeon 3.6

Table of Contents