Clearances & Installation - Fire Company EcoSmart Fire BK Series Installation, Operation And Maintenance Manual

E-nrg bioethanol is the only fuel to be used in this appliance.
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
engLiSh
Clearances & Installation
Top Tray
the incorporation of a top tray into your setting protects against heat
transference and aids in the collection of accidental spillage. Some
models come with top trays, others do not. top trays are available as
an accessory through the fire company or your local distributor.
The Fire Company Pty Ltd is not liable for any injuries or damages
sustained through the use of Top Trays not manufactured by The
Fire Company Pty Ltd;
When installing multiple Burners a maximum of three [3] Burners may
be installed into the one top tray (excluding the XL Series which can
only have one [1] Burner per top tray). Special considerations should
be made to multiple Burner installations in order to avoid potential
accidents. contact your local distributor about design and analysis
advice to minimise adverse impacts.
Environmental Conditions
WARNING: Ensure that your fire is positioned away from flammable materials and other
sources of ignition at all times. Pay very close attention to positioning the fire away from
items that may move as a result of wind and drafts. For example trees/branches/curtains/
paper and the like.
the base and the sides of the burner must never come into direct contact with combustible
materials.
Side clearances to fixed and stable furniture items that are not susceptible to movement such as
lounges or patio furniture must remain a minimum of 600mm [23.6in] away from the flame at all
times.
overhead clearances to items that are susceptible to movement
(e.g. curtains/trees) must remain a minimum of:
- Indoors: 1500mm [59.1in] away from the flame at all times.
- Outdoors: 2000mm [78.7in] away from the flame at all times.
note: Stainless steel will rust or corrode over time if contamination or debris is not cleaned
or removed immediately. When not in use, it is recommended that you protect your fireplace
from water damage or corrosion with a protective cover and always use the Burner Lid
included with your model to safeguard the burner.
A fire extinguisher is strongly recommended (AB:E in Australia / ABC in USA).
www.ecosmartfire.com
Top Trays provided by The Fire Company are fitted directly into the
Burner shelf from above. the Burner is then inserted into the top tray
setting and adjusted (using the levelling screws) to sit flush.
the size of the cut-out should not give more than 5mm [0.196in]
clearance. top trays must not be more than 200% of the total size
of the corresponding Burner.
For cut out dimensions for your model please contact your local
distributor.
Physical model dimensions should be verified against cut out
dimensions BEFORE installation begins to confirm tolerances align.
note: top trays are not required in uSA and canada.
[59.1]
1500mm
Indoor Clearances
Outdoor Clearances
[23.6]
600mm
[78.7]
2000mm
[23.6]
600mm
e-NRG Bioethanol is the only fuel to use in this appliance.