Summary of Contents for Fire Company STARTHERM Mini R1V

  • Page 1 Operating Manual Fireplace inserts...
  • Page 2 PREFACE - QUALITY PHILOSOPHY CONTENTS OF OPERATING INSTRUCTIONS Certified Quality Service and maintenance You have decided in favour of a SPARTHERM fireplace - thank you for your confi- Closing function of the door Type plate dence in our company. 1.1.1 Conversion of closing function on the fire door Ash pan and grate Window...
  • Page 3: Certified Quality

    1. CERTIFIED QUALITY No self-closing door function: multiple occupancy is not permitted, i.e. the fire 1.1.1 CONVERSION OF CLOSING FUNCTION ON THE 2.1.2 T YPES OF WOOD area must be connected to its own stack or chimney. FIRE DOOR The different types of wood all contain roughly the same amount of heat OUR FIREPLACE INSERTS ARE CERTIFIED WITH A CE MARK IN ACCORD- Note: when a stack or chimney has multiple fireplaces connected to it, it must energy per net kg of wood mass.
  • Page 4: Initial Start-Up

    • The wood should be stored in a protected, dry and well ventilated place. 3. BURNING ** The actual quantity of wood depends on the type of wood • If you have no external combustion air inlet, ensure you have a sufficient and its related properties.
  • Page 5 Caution: The important thing about this process is that it prevents rapid Depending on the length of firewood and the dimensions of the combustion burn-up in a downwards direction. The lighting of firewood in fire areas, chamber, narrow fireplace inserts are filled with firewood that points towards and the correct stacking of that firewood together with initial observation of the front.
  • Page 6: Technical Information

    3.3 FIRING/ADDING WOOD 4. TECHNICAL INFORMATION 4.2 OPERATION WITH OPEN DOOR 4.4 FIRE SAFET Y / IN THE FIREPLACE • Depending on weather condition, move the actuating lever more of less • Open operating mode is only permitted if the fireplace unit was inspected 4.4.1 SPECIAL FIRE SAFET Y PRECAUTIONS RELATING 4.1 HEATING DURING THE TRANSITION PERIOD into centre position or slightly above it (closing the supply of air).
  • Page 7 4.4.2 SPECIAL PRECAUTIONS FOR THE FIRE PRO- In addition, the area starting from the straight radiation area of the effective TECTION OF ADJACENT COMPONENTS CON- firebox opening must be protected by 300 mm to the left and to the right (see STRUCTED OF FLAMMABLE MATERIALS illustration).
  • Page 8 4.4.3 FIREPLACE INSERTS - AREA OF DIRECT RADIANT HEAT Distance in the area of direct Distance in the area of direct Distance in the area of direct radiant heat of the view pane [mm] radiant heat of the view pane [mm] radiant heat of the view pane [mm] Fireplace Insert Fireplace Insert...
  • Page 9 Closing the fire door: 4.5 CLEANING OF VERTICALLY-ORIENTED SLIDING 4.5.1 CLEANING OF ROUND OR ANGLED VERTICALLY Closing the firebox door: DOORS SLIDING DOORS 1. Carefully close the fire door. 1. Close the firebox door carefully and keep it lightly pressed in. 2.
  • Page 10: Service And Maintenance

    5. SERVICE AND MAINTENANCE 5.4 CLEANING AND MAINTENANCE The fire area, the hot gas draught and the flue should be cleaned at regular CAUTION! Never clean your fireplace insert while it is hot or warm. Only touch the frame of the door intervals.
  • Page 11 5.5 SMARTCLOSE DOOR LOCK 6. HELP Fireplace inserts with SmartClose door Problem Cause, explanation Chapter, note Solution locking mechanisms must be lubricated Glass becomes You did not use the correct combustion materials. Use natural, bulky bits of timber compliant with BImSchV §3 (German legislation). at regular inter vals to assure prob- sooted heavily, Fill the fireplace with a small amount of fuel and light it with the damper fully open...
  • Page 12 7. DISASSEMBLY 8. DISPOSAL Problem Cause, explanation Chapter, note Solution 7.1 SAFET Y INFORMATION FOR DISASSEMBLY 8.1 DISPOSING OF THE PACK AGING Smoke escapes Air-extracting equipment is switched on, e.g. kitchen extractor fan. Ensure that all air-extracting equipment is switched off. when adding wood Wood added prematurely, on top of unburned wood.
  • Page 13: Standards And Regulations

    9. APPENDIX 9.2 STANDARDS AND REGULATIONS Relevant regulations – without claim to completeness: 9.1 ACCESSORIES • FeuVo: Firing installation regulation of the respective german state. • LBO: State construction regulations or fire protection regulations. Combustion control S-Thermatik Neo • VKF: Association of Fire insurances of the Cantons (Switzerland). Secondary air control S-Kamatik 2 •...