Fixing the operator to the wall ...................7 Fixing the guide to the door ..................9 Radar ........................9 Photocell .........................13 Before using the GIRO SOCIAL DOOR OPERATOR, read and follow Closing the operator cover ..................14 all instructions contained in this manual carefully. Maintenance ........................15 Defects, Probable causes, and Corrections ............15...
TOOLS NEEDED FOR INSTALLATION CARE WITH THE ELECTRICAL INSTALLATION To avoid damage to the wiring, it is important that all conductors be properly fixed Here are some tools needed to install the operator: to the operator. Wiring must be done through conduits, passing internally through the base of the floor, ensuring that none of the wiring conductors are trapped and damaged.
TECHNICAL CHARACTERISTICS INSTALLING AND FIXING THE OPERATOR PARAMETER AND TECHNICAL CHARACTERISTICS OPERATOR TYPE PIVOTING PIVOTING RATED VOLTAGE 220 V 220 V NOMINAL FREQUENCY 60 Hz 50 Hz RATED POWER 150 W 150 W MOTOR ROTATION 3492 rpm 2910 rpm NOMINAL CHAIN 1,2 A 1,2 A ARM FIXING...
If the door is an internal opening, secure the operator so that the drive arm is FIXING THE GUIDE TO THE DOOR slightly above the top of the door leaf. After fixing the operator to the drive arm, secure the aluminum guide to the door so that the drive arm does not extend beyond the limit and do not move off the guide (fixe the aluminum guide in the center of the door).
Page 6
- Detection area: - long - narrow NOTE To reverse the position of the antenna, push Knowing the board This side out the locks in opposite direction from each other, remove the board and fit it back into the desired position (figure on the side).
PHOTO / RADAR / EXTERNAL RADAR / INTERNAL RADAR / Internal (polarized) connector / Gray Cable Fixing the radar on the cover Fit and fix the radar stand near the Giro operator. RADAR Precautions -Do not install the receiver directly facing the sun;...
MAINTENANCE Photocell connection Before any Maintenance, remove the power cord from the electrical network. DEFECTS, POSSIBLE CAUSES AND CORRECTIONS It will mention some DEFECTS, PROBABLE CAUSES AND CORRECTIONS, which may occur in your operator, in case you need to occur Maintenance. DEFECTS PROVáVEIS CAUSAS CORREçõES...
INVERTER BOARD INSTALLATION After the inverter is energized for the first time, start the motor by pressing the OK button or by a command on RADAR1 or RADAR2 or RECEIVER. The door should initiate an opening movement, for better visualization of the movement leave it in The electrical connections of the board must be made according to the diagram contained in this manual.
Page 10
CODE EXISTING CONFIGURATION FUNCTION MEANING OF CONFIGURATION FUNCTION PRINTED FOR THIS FUNCTION ON DISPLAY Semi-automatic mode (SA) or pause time in seconds Sau/t00 to t99 Closing limit switch. [s]. Door model (Bona, Flash, Tore, Avanti, Replacement and Pivoting). Disables the operation of electromagnetic lock (tof) or tof or t01 to t99 enable locking and the activation time of it (t01 to t99) Sensibility of anti-smashing at closing (force at closing).
EXISTING CONFIGURATION FUNCTION MEANING OF CONFIGURATION INCORPORATED PHOTOCELL FOR THIS FUNCTION Opening speed [Hz] when there anti panic signal, if 001 or 025 In this board there is a incorporated photocell, ie it is only necessary to connect the door is configured to open in this situation. the light transmitter and the infrared light receiver to the "TXFOT"...
TST JUMPER POSSIBLE ERRORS AND DEFECTS When removing the TST jumper, the OK button is used to slowly rotate the motor in a certain direction while the button is pressed, and the SHIFT button is used to Errors turn the motor in the opposite direction of the OK button while it is pressed. When the TST jumper is replaced, the inverter returns to normal operation.
Page 13
DEFECT DEFECT CAUSE SOLCTION Enter the function menu The door does not and function 4 (F4), match the installed There is a different route change from nrt to rSt, location route (brakes recorded the route from exit the menu via out, before closing stop or the local installed.
Need help?
Do you have a question about the GIRO and is the answer not in the manual?
Questions and answers