Download Print this page

ETC Paradigm P-LCD Series Installation Manual page 3

Advertisement

E T C I n s t a l l a t i o n G u i d e
Step 2:
Step 3:
Step 4:
Installing the Termination PCB to the Rack Panel
Step 1:
N o t e :
Step 2:
Step 3:
Uni son Pa r adi gm T ou chs cr ee n Rack Pa ne l
Plug the LinkPower connector into the two pin LinkPower receptacle on the termination
PCB.
Terminate the installed Auxiliary power wire to the red and black Auxiliary power pigtail
wires. Using two Wago connectors connect the (typically red) installed wire(s) with red
pigtail wire and connect the (typically black) installed wire(s) with black pigtail wire.
Plug the Auxiliary power connector into the two pin Aux power receptacle on the
termination PCB.
Position the PCB on the four standoffs on the back of the rack panel and secure with two
M3x10mm pan head screws on the RJ11 side of the PCB only.
The termination PCB can be installed in any orientation to accommodate wiring.
Place the bracket and RJ45 assembly (if used) on top of the PCB. Secure the PCB to the
backbox through the remaining holes in the PCB with two M3x10mm pan head screws.
A ground connection is required for all Touchscreen assemblies. Using one three position
Wago connector, connect the (typically green and yellow) installed wire(s) with the ground
wire pigtail (with attached spade), provided in the installation kit, and the ground wire
attached to the rack panel.
Paradigm P-LCD Series
Installed ground wire
Ground wire pigtail (spade connector to the termination PCB)
Ground wire pigtail (ring terminal connected to the rear rack panel)
Page 3 of 4
El ect r on ic T he at r e Con tr o ls , I nc.

Advertisement

loading