Download Print this page

Remote Access To The System; Specification - jablotron JA-65X Installation Manual

Digital communicator

Advertisement

6 Remote access to the system

The JA-60U modem can be used for the remote connection of
the control panel to a personal computer with Comlink software or
a remote JA-60E keypad using a standard telephone line. It is
necessary to know the remote control access code for the system
(see 3.2).
Details on how to use the JA-60E keypad remotely can be
found in the JA-60E manual.
A personal computer connected remotely works the same way
as when it is wired directly to the control panel (see also
installation manual of the control panel). Only downloading or
uploading of extensive data (like event list downloading, digital
communicator setting etc.) takes a slightly longer time compared
to a direct PC connection to the control panel.
6.1
Establishing connection with a remote control
panel by computer
Start Comlink SW on a computer equipped with a JA-60U
modem. The dialing dialog requires the following data:
telephone number of the called control panel
dialing method (tone or pulse)
control panel's remote access code (must be identical
as code programmed in the control panel - 8 digits)
optional bypassing of answering machine (if this
option was programmed in the control panel); if the
connection can not be established, try to enter
"space" after the last digit
optional call back feature, if you want the control
panel to call your computer back (that way the end
user's telephone will be charged for the remote
access communication)
Digital communicator JA-65X
"Dialing in" dialog of the Comlink software

7 Specification

Digital communication to:
• a monitoring station,
• 5 SMS messages or Pager dialing,
• 2 voice messages, modem communication with a remote
PC (ComLink SW + JA-60U modem),
• remote keypad access with JA-60E and JA-60U
Monitoring station formats
Contact ID, Ademco, Telemax, Franklin, Radionics, SurGard,
DTMF2300, (198 reports codes)
can be connected to analogue interfaces TBR 21/1998, EG
201 121 V1.13/2000, AS/ACIF S002/2001 (Australia)
JABLOTRON ALARMS a.s. hereby declares that
the JA-65X is in a compliance with the relevant
Union harmonisation legislation: Directives No:
2014/35/EU, 2014/30/EU, 2011/65/EU. The original
of the conformity assessment can be found at www.jablotron.com
- Section Downloads.
Note: Although this product does not contain any harmful
materials we suggest you to return the product to the dealer or
directly to the producer after usage.
7/7